Electrical connection
8.3
Connecting the mains cable and the mains connection cable
DANGER
Incorrect connection of the mains connection cable between
master and slave!
If the mains connection cable between master and slave is
connected to the terminals XD1 at the master, the power supply
for the slave is not switched off via switch S1 in the pedestrian
gate. Touching live parts can be lethal.
›
Connect the mains connection cable on the master to
terminals X1 and on the slave to terminals XD1.
ä
Wiring
diagram, separate document.
NOTICE
Incorrect connection of the mains connection cable between
master and slave!
Incorrect connection of the mains connection cable between
master and slave will cause the pedestrian gate to malfunction.
›
Connect the mains connection cable on the master to
terminals X1 and on the slave to terminals XD1.
ä
Wiring
diagram, separate document.