Turnigy REAKTOR / iCharger 206b calibrating:
First measure the voltages with a multimeter.
Vi
= Voltage input / power source output where charger will be connected
Vo
= Voltage output on the lipo on it's discharge plug
C1
= Voltage of lipo cell 1
C2
= Voltage of lipo cell 2
C3
= Voltage of lipo cell 3 4 5 6
Power-up the charger: Press and hold
all 4 buttons
at startup until you here 3
beeps
Press and hold "
stop
" button for 3 seconds until beep
- Make sure you have connected your lipo (charge and balance plug) at this
moment
Press and hold 3 buttons (
Dec
/
Inc
/
Start-Enter
) until you here a beep
Now set
Vi
at desired value with the
< >
buttons, when done press
Start-Enter
Now set
Vo
at desired value with the
< >
buttons, press
Start-Enter
when done
Optional: You can also set Internal and External temperature at this point, and if you
press and hold
Start-Enter
for 3 seconds it will go to internal-resistance mode
Press "
stop
"
Press "
Inc
" to go to cell voltages
Press and hold 3 buttons (
Dec
/
Inc
/
Start-Enter
) until you here a beep
Now set
C1
at desired voltage value with the
< >
buttons, when done press
Start-
Enter
and set all other cell voltages
Press "
stop
" twice to exit when done!
Video guide:
http://www.youtube.com/watch?v=bEpEN6piv8s