Chapter 3 Management Interface Cabling
RS-232 DTE Interface Connection
Release TR3.2.1
Turin Networks
Page 9-41
4
Remove the back cover from the Traverse shelf. Refer to
Section 6—
Precautions and Common Procedures
Chapter 2—“Removing and Replacing Back Covers,” page 6-9 for
detailed instructions.
5
Bring the Category 5 cable over to the (J5) RJ-45 connector on the main
backplane.
6
Cut the Category 5 cable to the correct length.
7
Strip the cable and terminate on a RJ-45 plug using a crimp tool. RS-232
interface pinouts along with DB-9 and DB-25 pinouts are provided below.
Figure 9-28 RJ-45 Plug and RS-232 Pinouts
8
Insert the RJ-45 plug into the (J5) RJ-45 connector on the main backplane.
Figure 9-29 Traverse Main Backplane RS-232 Interface
Table 9-20 RS-232 DTE Interface Connection (continued)
Step
Procedure
(J5)
RS-232
DTE
Interface
(RJ-45)