Inductive sensor
For the food industry
BI15U-EM30WD-AP6X-H1141/3GD
Edition
•
2016-05-14T08:17:29+02:00
1 / 4
Hans Turck GmbH & Co.KG
ñ
D-45472 Mülheim an der Ruhr
ñ
Witzlebenstraße 7
ñ
Tel. 0208 4952-0
ñ
Fax 0208 4952-264
ñ
ñ
www.turck.com
Type code
BI15U-EM30WD-AP6X-H1141/3GD
Ident no.
1634855
Rated switching distance Sn
15 mm
Mounting conditions
flush
Assured switching distance
ð
(0,81 x Sn) mm
Repeatability
ð
2 % of full scale
Temperature drift
ð
± 10 %
ð
± 20 %,
ð
-25 °C ,
ï
+70 °C
Hysteresis
3…15 %
Ambient temperature
-40…+100 °C
in the explosion hazardous area see instruction
leaflet
Operating voltage
10… 30VDC
Residual ripple
ð
10 % U
ss
DC rated operational current
ð
200 mA
No-load current I
0
ð
20 mA
Residual current
ð
0.1 mA
Rated insulation voltage
ð
0.5 kV
Short-circuit protection
yes/ cyclic
Voltage drop at I
e
ð
1.8 V
Wire breakage / Reverse polarity protection
yes/ complete
Output function
3-wire, NO contact, PNP
Protective insulation
÷
Switching frequency
0.75 kHz
Approval acc. to
ATEX test certificate TURCK Ex-10002M X
Device designation
É
II 3 G Ex nA IIC T4 Gc/II 3 D Ex tc IIIC T110°C
Dc
Construction
Threaded barrel, M30 x 1.5
Dimensions
62 mm
Housing material
Stainless steel, V4A (1.4404)
Active area material
Plastic, LCP
Connector housing
plastic, PP
Admissible pressure on front cap
ð
10 bar
Max. tightening torque housing nut
75 Nm
Connection
Flange connector, M12 x 1
Vibration resistance
55 Hz (1 mm)
Shock resistance
30 g (11 ms)
Protection class
IP68 / IP69K
MTTF
874 years acc. to SN 29500 (Ed. 99) 40 °C
Switching state
LED yellow
■
ATEX category II 3 G, Ex Zone 2
■
ATEX category II 3 D, Ex Zone 22
■
Threaded barrel, M30 x 1.5
■
Stainless steel, 1.4404
■
Front cap made of liquid crystal poly-
mer
■
Factor 1 for all metals
■
Resistant to magnetic fields
■
Temperatures -40 °C … +100 °C
■
High protection class IP69K, for harsh
environments
■
Special double-lip seal
■
Protection against all common acid and
alkaline cleaning agents
■
Laser engraved label, permanently legi-
ble
■
DC 3-wire, 10…30 VDC
■
NO contact, PNP output
■
M12 x 1 male connector
Wiring Diagram
Functional principle
The inductive sensors for the food industry
are absolutely tight and resistant to cleaning
agents and disinfectants,thanks to the LCP
front cap and the stainless steel housing.
Derating curve