V02.00 | 2020/08
185
8.5.17
Command: Permanently deactivate UHF tags (Kill)
NOTE
The command code for fast processing with the loop counter is 0x2200 (hex.) or
8704 (dec.).
The
Kill UHF tag
command makes the tag memory unusable. After a kill command, the tag can
neither be read nor written. A kill command cannot be undone.
Request
Loop counter
See description of the output data, [
Command code
0x0200 (hex.), 512 (dec.)
Read/write head address
See description of the output data, [
Length of EPC
Enter the EPC size in bytes if a particular tag is to be deleted.
The EPC must be defined in the write data (start byte: 0). The
function of the length of the EPC depends on the command
used.
0: No entry of an EPC for executing the command. Only one
tag can be located in the detection range of the read/write
head.
> 0: EPC length of the tag to be deleted if an EPC is present
in the write data.
Start address
Not required
Length
1 byte
Command timeout
See description of the output data, [
Write fragment no.
0
Read fragment no.
See description of the output data, [
Write data, Byte 0...3
Password: ARRAY [0…3] OF BYTE
Write data, Byte 4...127
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0200 (hex.), 512 (dec.)
Length
Not required
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
0
Read fragment no.
See description of the input data, [
Read data
Not required