Setting
RFID channels – overview of the commands
160
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
8.5.1
Command: Idle
The
Idle
command switches the interface to Idle mode. The command execution is aborted. In
UHF applications the EPC is indicated if the read/write head is assigned parameters directly in
Presence sensing mode via the DTM.
Request
Loop counter
Not required
Command code
0x0000 (hex.), 0 (dec.)
Read/write head address
Not required
Length of EPC
Not required
Start address
Not required
Length
Not required
Command timeout
Not required
Write fragment no.
Not required
Read fragment no.
Not required
Write data
Not required
Response
Loop counter
See description of the input data, [
Response code
0x0000 (hex.), 0 (dec.)
Length
Length of the EPC of the tag in the detection range
Error code
See description of the input data, [
Tag within the
detection range
See description of the input data, [
Data (bytes) available
See description of the input data, [
Tag counter
See description of the input data, [
Write fragment no.
Size of the fragments
Read fragment no.
Size of the fragments
Read data, Bytes 0…n
EPC of the tag in the detection range
Summary of Contents for TN-UHF AUS-CDS Series
Page 1: ...Your Global Automation Partner Instructions for Use TN UHF CDS UHF Read Write Head ...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...
Page 97: ...V02 00 2020 08 97 Transfer the mapping to the POU Fig 94 Transferring the mapping to the POU ...