![turck TN-IOL2 Series Instructions For Use Manual Download Page 15](http://html1.mh-extra.com/html/turck/tn-iol2-series/tn-iol2-series_instructions-for-use-manual_1181745015.webp)
V01.00 | 2021/05
15
8
Setting and Parameterization
8.1
Settable functions and features
The following functions and properties can be set via the IO-Link interface:
n
Operating mode for SIO mode:
– Querying the presence of tags (
Tag presence
)
– Comparing tags (
Data update
)
– Alarm output
n
Output configuration Q1 and Q2: NC contact or NO contact
n
RSSI limit value for alarm outputs and setting the optimum detection range
n
Type of the alarm outputs: time-triggered or RSSI-triggered
n
Password
More information on setting the device via IO-Link is provided in the IO-Link parameter manual.
8.2
Setting with IO-Link function block
The read/write heads can be set and configured via IO-Link function blocks. The function blocks
for the CODESYS V3 and Siemens TIA V14 programming environments are available as free
downloads from
Further information on programming the function blocks is provided in the description of the
process data.
Function block for CODESYS V3
Fig. 7: Function block for CODESYS V3