Module Status
In addition to the status word, the module status is mapped to the end of the process data.
Bit
15
Bit
14
Bit
13
Bit
12
Bit
11
Bit
10
Bit
9
Bit
8
Bit
7
Bit
6
Bit
5
Bit
4
Bit
3
Bit
2
Bit
1
Bit
0
-
Force
Mode
-
-
-
COM
UV
V1
-
UV
V2
-
-
-
-
-
-
DIAG
Name
Value
Description
DIAG
0
-
1
Diagnostics available at the device.
UV V1/V2
-
V1 or V2 too low (< 18 V DC).
COM
0
-
1
Internal error, device-internal communication disturbed
Force Mode
0
-
1
The Force Mode is activated, which means, the actual output values may no
match the ones defined and sent by the field bus.