3.6
Universal Standard I/Os
The function description of the
unsafe
universal I/Os can be found in the separate documentation
User manual TBIP-L…-FDIO1-2IOL – Standard I/O channels.
3.7
IO-Link Master Channels
The function description of the
unsafe
IO-Link master channels can be found in the separate docu-
User manual TBIP-L…-FDIO1-2IOL - IO-Link master.
3.8
Configuration Memory
A pluggable memory stick is included in the scope of delivery of TBPN-L1-FDIO1-2IOL. It serves for
storing the safety function configured via Turck Safety Configurator.
It allows to transfer the configuration of one device to another device (device exchange).
the safety function is configured via Turck Safety Configurator (see
Turck Safety Configurator and Rockwell Studio 5000
).
3.8.1
Storing a Configuration
The safety function is automatically stored to the memory stick after a configuration has been
downloaded to the device via Turck Safety Configurator.
HINWEIS
Non-safety-related configurations as for example the IP address or the parameterization
of the IO-Link and the standard I/O channels will not be stored on the memory chip.
Storing a Configuration at Device Start
Prerequisites
Empty memory chip
Device has stored a valid configuration
Power supply switched-off
Procedure
Plug the empty memory chip into the device
Switch-on the power supply
The configuration will be loaded from the device to the memory stick during device start.
Summary of Contents for TBIP-L...-FDIO1-2IOL Series TBIP-L4-FDIO1-2IOL
Page 1: ...Your Global Automation Partner TBIP L FDIO1 2IOL Safety Block I O Module Instructions for Use...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Page 118: ...Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 2...