For Your Safety
This manual includes all information necessary for the prescribed use of the modules of type
TBIP-L…-FDIO1-2IOL. It has been specially conceived for personnel with the necessary qualifica-
tions.
The product is designed according to state-of-the-art technology. However, residual risks still exist.
Observe the following warnings and safety notices to prevent damage to persons and property.
Turck accepts no liability for damage caused by failure to observe these warning and safety notices.
2.1
Intended Use
The safe hybrid safety module TBIP-L…-FDIO1-2IOL is a filed bus device for an EtherNet/IP™ Safety
Controller with CIP Safety. It can be used in applications:
up to SIL 3 (according to IEC 61508)
up to SIL CL3 (according to EN 62061)
up to Category 4 and Performance Level e (according to EN ISO 13 849-1)
The module serves for controlling signal devices as for example emergency stop buttons, position
switches or OSSDs which are used to ensure human, material or machine protection.
Read these instructions carefully before using the product. This is to avoid possible damage to per-
sons, property or the device.
2.2
Foreseeable Misuse
The safety module is not suitable for:
the use in explosive areas
outdoor use
The permanent use in liquids
Modifications to the Device
It is not permitted to modify the technical function or the construction of the device.
2.3
General Safety Instructions
The Performance Level as well as the safety category according to EN ISO/ISO 13849-1 depend
on the external wiring, the application, the choice of the control devices as well as their arrange-
ment on the machine.
The user has to execute a risk assessment according to EN ISO/ISO 12100.
Based on the risk assessment a validation of the complete plant/machine has to be done in accor-
dance with the relevant standards.
Operating the device beyond the specification can lead to malfunctions or to the destruction of
the device.
Observe the installation hints.
Summary of Contents for TBIP-L...-FDIO1-2IOL Series TBIP-L4-FDIO1-2IOL
Page 1: ...Your Global Automation Partner TBIP L FDIO1 2IOL Safety Block I O Module Instructions for Use...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Page 118: ...Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 2...