Properties of the IO-Link channels
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
14
2.6
Parameters
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Basic
0
-
1
SRO15
-
SRO13
-
2
-
3
EN DO15
-
EN DO14 -
IO-Link
Port 1
4
GSD
Quick
Start-Up
Data storage mode Mode
5
Cycle time
6
Mapping process
output data
Mapping process
input data
Diagnostics
deactivate web
server
Process
input data
invalid
Revision
7 to 11
reserved
12 Vendor
ID
(LSB)
13
Vendor ID (MSB)
14
Device ID (LSB)
15
Device ID
16
Device ID
17
Device ID (MSB)
18
reserved
19
reserved
Port 2
20 to
35
Assignment similar to port 1 (byte 4 to 19)
Name
Meaning
Value
SRO
Manual output reset after overcurrent
0
0 = no
A
The output switches on automatically after an overload.
1
1 = yes
The output is manually switched-off after an overload until a new
set-command is given (rise and fall).
EN DO
Activate output
0
0 = no
A
The output at pin 2 is deactivated.
1
1 = yes
The output at pin 2 is activated.
Mode
0000
IO-Link without
validation
A
Pin 4 is operated in IO-Link mode.
The master does not check if the connected device matches the
configured one.
Summary of Contents for TBIP-L...-FDIO1-2IOL Series TBIP-L4-FDIO1-2IOL
Page 1: ...Your Global Automation Partner TBIP L FDIO1 2IOL Safety Block I O Module Instructions for Use...
Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...
Page 118: ...Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com 2...