background image

Your Global Automation Partner

Instructions for Use

TBEN-L…-SE-M2

10-Port Ethernet Switch

Summary of Contents for TBEN-L SE-M2 Series

Page 1: ...Your Global Automation Partner Instructions for Use TBEN L SE M2 10 Port Ethernet Switch ...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Page 3: ...nciple 10 4 4 Functions and operating modes 11 4 4 1 SNMP agent 11 4 4 2 Neighborhood detection via LLDP Link Layer Discovery Protocol 11 4 4 3 Prioritization classification of data packets via QoS 11 4 4 4 DHCP 11 4 4 5 Network redundancy 11 4 4 6 Routing 12 4 4 7 Firewall 12 4 4 8 NAT Network Address Translation 12 4 4 9 Mirroring mirroring switch ports 12 4 4 10 IGMP Internet Group Management P...

Page 4: ... 8 1 4 SNMP setting up SNMP 35 8 1 5 DHCP setting up a DHCP server 37 8 1 6 LLDP configuring neighborhodd detection 40 8 1 7 QoS prioritizing or classifying data packets 41 8 1 8 Mirroring configuring the mirroring of switch ports 46 8 1 9 Redundancy configuring network redundancy 47 8 1 10 Routing configuring rules routes 47 8 1 11 Firewall configuring firewall rules 48 8 1 12 NAT configuring NAT...

Page 5: ...ry if not avoided WARNING WARNING indicates a dangerous situation with medium risk of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on ...

Page 6: ...switch n Closing caps for M12 sockets n Labelling clips 2 3 Legal requirements The device falls under the following EU directives n 2014 30 EU electromagnetic compatibility n 2011 65 EU RoHS directive n 2014 34 EU ATEX directive 2 4 Turck service Turck supports you with your projects from initial analysis to the commissioning of your applic ation The Turck product database under www turck com cont...

Page 7: ...d ance with the intended use Turck accepts no liability for any resulting damage 3 2 General safety notes n The device may only be assembled installed operated parameterized and maintained by professionally trained personnel n The device may only be used in accordance with applicable national and international regu lations standards and laws n The device only meets the EMC requirements for industr...

Page 8: ...ntial bonding in the Ex area n Ensure impact resistance in accordance with EN IEC 60079 0 alternative measures Install the device in the TB SG L protective housing available in the set with Ultem window ID 100014865 and replace the service window with an Ultem window Install the device in an area offering impact protection e g in robot arm and attach a warning DANGER Only connect and disconnect ci...

Page 9: ... with a transmission speed of 10 100 Mbps For connecting the supply voltage 4 pin TBEN L4 7 8 connectors 5 pin TBEN L5 7 8 connectors or 5 pin M12 connectors TBEN LL are available 4 1 Device overview mm Inch 38 8 1 53 Ø 6 3 0 25 218 8 58 230 4 9 07 6 0 24 60 4 2 38 Ø 6 3 0 25 24 0 95 XF8 XF10 XF7 XF6 XF5 XF4 XF9 XF3 XF2 XF1 XD2 XD1 green 29 5 1 16 Fig 1 Dimensions TBEN L4 SE M2 mm Inch 38 8 1 53 Ø...

Page 10: ...ion tested n Fully potted module electronics n Protection class IP65 IP67 IP69K n UV resistant according to DIN EN ISO 4892 2 n Metal connectors n Ethernet ports 2 M12 X coded 1 Gbps 8 M12 D coded 10 100 Mbps n Web based management n Configurable LAN and WAN zones n Configurable Layer 3 features 4 3 Operating principle The TBEN L SE M2 is used to build industrial Ethernet networks according to IEE...

Page 11: ...SCP Differentiated Services Codepoint DDSCPs are used to classify data packets A DSCP 0 63 specifies a forwarding behavior for a data packet i e it determines how a packet is handled 4 4 4 DHCP The switch supports the following DHCP options n DHCP server n DHCP client n DHCP server option 82 port based IP address assignment 4 4 5 Network redundancy The switch supports network redundancy via STP an...

Page 12: ...based and apply to all data packets or only to UDP based or TCP based packets 4 4 8 NAT Network Address Translation If IP forwarding forwarding of data packets between networks with different IP address ranges is activated IP addresses of one network are translated into IP addresses of another network Example IP addresses of network participants of an internal network are assigned to IP ad dresses...

Page 13: ... there is no potentially explosive atmosphere present Observe requirements for Ex approval Unscrew the housing Use Torx T8 screwdriver Replace the service window with the enclosed Ultem window Place the device on the base plate of the protective housing and fasten both together on the mounting plate see 14 Connect the device see 17 Mount and screw the housing cover according to the following figur...

Page 14: ...h the module to the mounting surface with two M6 screws The maximum tighte ning torque for the screws is 1 5 Nm Avoid mechanical stresses Optional Ground the device 218 5 58 M6 2x max 1 5 Nm Fig 5 Mounting the device onto a mounting plate 5 3 Mounting the device outdoors The device is UV resistant according to DIN EN ISO 4892 2 Direct sunlight can cause material abrasion and color changes The mech...

Page 15: ... XF2 XF3 XF4 XF9 2 x 15 nF XD2 XF5 XF6 XF7 XF8 XF10 XD1 XF1 XF2 XF3 XF4 XF9 Fig 6 TBEN L4 SE M2 equivalent wiring dia gram and shielding concept Fig 7 TBEN L5 SE M2 equivalent wiring dia gram and shielding concept 2 x 15 nF XD2 XF5 XF6 XF7 XF8 XF10 XD1 XF1 XF2 XF3 XF4 XF9 Fig 8 TBEN LL SE M2 equivalent wiring dia gram and shielding concept ...

Page 16: ...g is only connected to the ref erence potential of the installation when the module is mounted In the device variants TBEN L5 SE M2 and TBEN LL SE M2 the earthing can also be connected via pin 5 of the connector for the supply voltage 5 4 3 Grounding the device Grounding the device mounting on a mounting plate For mounting onto a mounting plate Fix the module with an M6 metal screw through the low...

Page 17: ...Risk of explosion through spark ignition When used in Zone 2 and Zone 22 Only disconnect and connect circuits when no voltage is applied Only use connecting cables that are approved for use in potentially explosive at mospheres Use all connectors or seal them with blind plugs Observe requirements for Ex approval 6 2 Connecting network segments To connect the Ethernet network segments the device ha...

Page 18: ...8 4952 0 F 49 208 4952 264 more turck com www turck com Fast Ethernet ports 10 100 Mbps Fig 12 M12 Fast Ethernet connector Connect the device to Ethernet according to the pin assignment below v 4 1 3 2 XF1 XF8 1 TX 2 RX 3 TX 4 RX flange FE Fig 13 M12 Fast Ethernet connector ...

Page 19: ...connecting the supply voltage Connect the device to the power supply according to the pin assignment shown below w v 1 2 3 4 1 RD 24 VDC V2 2 GN 24 VDC V1 3 WH GND V1 4 BK GND V2 1 2 3 4 X1 X2 1 BK GND V2 2 BU GND V1 3 GNYE FE 4 BN 24 VDC V1 5 WH 24 VDC V2 3 4 5 2 1 w v 3 4 5 2 1 X1 X2 Fig 16 TBEN L4 pin assignment power supply connectors Fig 17 TBEN L5 pin assignment power supply connectors Conne...

Page 20: ...ly voltage Connect the device to the power supply according to the pin assignment shown below Always seal unused connectors with suitable screw caps or blind caps The tightening torque for the screw caps is 0 5 Nm 3 1 2 4 FE 1 3 2 4 FE XD1 XD2 1 24VDC V1 2 GND V2 3 GND V1 4 24VDC V2 FE Fig 19 Pin assignment power supply connectors Connector Function XD1 Power feed XD2 Continuation of the power to ...

Page 21: ...1 6 3 1 Supply concept The device is supplied via V1 All Ethernet ports are galvanically isolated V2 is fed through V1 V2 V1 V2 Fig 20 Supply TBEN L4 SE M2 Fig 21 Supply TBEN L5 SE M2 V1 V2 Fig 22 Supply TBEN LL SE M2 ...

Page 22: ...lt user for the web server is admin the default password is password Enter user name and password in the login field on the start page of the web server Click Login NOTE The password is transmitted in plain text for HTTP connections The password is only encrypted if access to the web server is established via an HTTPS connection 7 1 2 Securing device access with password NOTICE Inadequately secure...

Page 23: ...evice The switches are located under a service window together with the USB ports and the SET button 5 4 3 2 1 0 9 8 7 6 5 4 3 2 1 0 9 8 7 6 2 1 3 ON SRV USB Host Set Mode x 10 x 1 Fig 23 Switches for setting the IP address Open the service window above the switches Set the rotary coding switch to the desired position according to the table below Set DIP switch Mode to the desired position accordi...

Page 24: ...tomatic address assignment The DHCP server assigns a permanent IP address to the client n Dynamic address assignment The IP address assigned by the server is only reserved for a certain period of time After this time has elapsed or after the explicit release by a client the IP address is reassigned n Manual address assignment A network administrator as signs an IP address to the client In this cas...

Page 25: ...ol if the switch is con nected to the PC via one of its LAN ports Connection to a WAN port is not possible Connect the device to the PC via the Ethernet interface Open the Turck Service Tool Click Search or press F5 Fig 24 Turck Service Tool start dialog Turck Service Tool shows the connected devices Fig 25 Turck Service Tool found devices ...

Page 26: ...r press F2 Fig 26 Turck Service Tool select the device to be addressed NOTE Clicking the device s IP address opens the web server Change the IP address and the network mask if necessary Accept the changes with Set in device Fig 27 Turck Service Tool Change device configuration NOTE An IP address assigned vie the Turck Service Tool is not stored permanently in the switch ...

Page 27: ... the web server is admin the default password is password Click Configuration Ò IP Change IP address and subnet mask if applicable as well as default gateway for zone LAN and or or zone WAN Zone WAN only appears if at least one of the switch s interfaces has been assigned to the WAN under Interfaces 30 Write the new IP address subnet mask and default gateway via Set Addresses into the device Fig 2...

Page 28: ... transmitted in plain text for HTTP connections The password is only encrypted if access to the web server is established via an HTTPS connection In the delivery state or after a factory reset the default settings are as follows n User admin n Password password 7 3 1 Authorization levels The following table lists the authorization levels and the associated user rights Authorization level Meaning R...

Page 29: ...nance Ò Users Ò Users Select the authorization level and create the new user via Add user Fig 29 Web server Add user NOTICE Inadequately secured devices Unauthorized access to sensitive data Change password after first login Turck recommends using a secure password Adapt the password to the requirements of the network security concept of the system in which the devices are installed ...

Page 30: ... the device are stored non fail safe in the device Un saved configuration changes are displayed via the Nonpersistant Configuration ad dition on the web server interface In order to store a changed configuration fail safe it must be saved via Configuration changed Ò Make current configuration persistent 55 8 1 1 Interfaces configuring Ethernet interfaces Interfaces is used to configure the Etherne...

Page 31: ...duces the forwarding of broadcast messages The function should only be activated if problems occur due to broadcast storms In PROFINET applic ations relevant PROFINET frames may be sup pressed if Broadcast Storm Protection is activated Flood unknown Multicasts Unicasts On Activates the forwarding of multicast or unicast telegrams to all ports The function must be activ ated for PROFINET applicatio...

Page 32: ... web server is described in the chapter Commission ing 27 8 1 3 LAN WAN VLAN coding switches and VLAN configuring network zones Zones In the Zones area the Ethernet ports of the switch are assigned to the LAN or WAN network zones If ports are assigned to the WAN an IP address for the WAN must be assigned under IP Assign the zones and write them to the device via SET ZONES Fig 31 Webserver zone ass...

Page 33: ...s are assigned to the previously defined VLANs Assign the VLAN ID and name if necessary and create them via ADD ID Set the VLAN tag on the Ethernet port to enabled and enter the VLAN ID under Default VLAN ID to make the assignment Fig 32 Web Server defining VLAN IDs and assigning Ethernet ports ...

Page 34: ...VLAN Option Description Not a member The port is not assigned to a VLAN Untagged The port is an untagged member of the VLAN Forwarded packets are untagged The VLAN is port based which means one VLAN can be set per switch port Tagged The port is a tagged member of the VLAN All packets forwarded by the interface are tagged The packets contain VLAN information Tagged VLANs allow multiple VLANs to be ...

Page 35: ...re configured Configure and transfer settings to the device with SET SNMP User The SNMP User section contains a list of all users created under Add User for SNMP version 3 REMOVE is used to delete created SNMP users Fig 33 Webserver configuring SNMP Add User In the section Add User SNMP users are created for the authentication of devices with SNMP V3 Assign user name User Name and passwords Add us...

Page 36: ...ts a trap community The switch sends traps on the following events Trap Description Link up A new connection is established a device is connected to one of the ports Link down The connection to a connected device is interrupted Reboot The switch is restarted Under Destination specify the IP address of the device on the network that is to receive the traps Under Community specify the community to w...

Page 37: ...erver The network zone WAN only appears if Ethernet ports have been assigned to the WAN 32 and an IP address has been assigned to the WAN zone under 27 If necessary define one or more DNS servers By default the Google DNS server 8 8 8 8 is used Send the configuration to the device via SET Fig 35 Webserver DHCP server configuration DHCP Mode 82 only In DHCP mode 82 fixed IP addresses are assigned t...

Page 38: ...ss is to be assigned independently of the lease time Static addresses are permanently stored They are not deleted after the Aging Time has expired or when the switch is restarted Enter the IP address that is to be permanently assigned This IP address must be beyond the previously defined IP address range Enter the MAC address of the device that will be permanently assigned this IP address Fig 36 W...

Page 39: ...nnected device that sends a DHCP request If further devices are connected to the port these devices receive an IP address from the DHCP address pool Enter IP addresses at the respective port Send the configuration to the device via SET Fig 37 Web Server Ethernet port dependent IP address assignment Active Leases The section Active Leases contains a list of devices that have already been assigned a...

Page 40: ...tion Set up LLDP port by port for incoming Receive or for incoming and outgoing Receive Transmit Transfer settings to the device with SET Fig 38 Webserver setting up LLDP a The table below shows a list of all neighboring devices Fig 39 Webserver LLDP neighboring devices RELOAD restores the original configuration of the LLDP settings UPDATE NEIGHBORS updates the list of adjacent devices ...

Page 41: ...elegrams that have been classified via DSCP All other telegrams are then processed Default Queue Q0 weighted 1 Queue 0 the data is processed with a weighting of 1 Q1 weighted 2 Queue 1 the data is processed with a weighting of 2 Q2 weighted 3 Queue 2 the data is processed with a weighting of 3 Q3 weighted 6 Queue 3 the data is processed with a weighting of 6 Q4 weighted 12 Queue 4 the data is proc...

Page 42: ... with the web server 42 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com Fig 40 Web server QoS port wise prioritization of telegrams Set the prioritization for Ethernet ports Accept the changes via SET ...

Page 43: ...igned based on their PCP priorities Default settings PCP Value Transmit Queue PCP Value Transmit Queue 0 Q1 weighted 2 4 Q4 weighted 12 1 Q0 weighted 1 5 Q5 3rd strict 2 Q2 weighted 3 6 Q6 2nd strict 3 Q3 weighted 6 7 Q7 1st strict Fig 41 Web server QoS PCP Queue Mapping Set the queue mapping Accept the changes via SET ...

Page 44: ...defines to which output queues telegrams are assigned based on their DSCP priorities Default settings DSCP Value Transmit Queue DSCP Value Transmit Queue 0 7 Q0 weighted 1 32 39 Q4 weighted 12 8 15 Q1 weighted 2 40 47 Q5 3rd strict 16 23 Q2 weighted 3 48 55 Q6 2nd strict 24 31 Q3 weighted 6 56 63 Q7 1st strict Fig 42 Web server QoS DSCP Queue Mapping Set the queue mapping Accept the changes via SE...

Page 45: ...he following example telegrams that were classified via a DSCP of 5 received the highest priority 7 Default settings DSCP Value Transmit Queue DSCP Value Transmit Queue 0 7 0 21 39 4 8 15 1 40 47 5 16 23 2 48 55 6 24 31 3 56 63 7 Fig 43 Web server QoS DSCP Ò PCP queue mapping Set the queue mapping Accept the changes via SET ...

Page 46: ...more switch ports to another port Only the in coming telegrams mirror recieve only the outgoing telegrams mirror transmit only or both directions mirror revceive and transmit can be mirrored Define the port to which the port or ports to be mirrored are to be mirrored under Destination Ò Destination Interface Activate the desired mirroring at the switch ports XF1 XF10 Transfer settings to the devic...

Page 47: ...es forwarding rules routes for data transmission between the configurable LAN and WAN network zones NOTE IP forwarding forwarding of data packets between networks with different IP address ranges must be activated Add Route Example Telegrams from station 1 at port 2 of the switch will be forwarded to station 2 of another net work Station 1 Station 2 IP address 10 17 2 12 IP address 192 168 1 100 W...

Page 48: ...all rules The firewall is deactivated when the device is delivered and must first be activated e g via a block any rule all telegrams are blocked After that exceptions to this rule can be defined Firewall rules can be created separately for incoming and outgoing packets In addition forwarding rules can be defined Application example defining firewall rules Access to the switch via HTTP port 80 is ...

Page 49: ...V02 00 2021 11 49 Set up second incoming rule that blocks access via HTTP port 80 Fig 47 Web server block access via HTTP Create firewall rule via SAVE Fig 48 Web server incoming rules ...

Page 50: ...rt NOTE IP forwarding forwarding of data packets between networks with different IP address ranges must be activated Add NAT Rule Source NAT In the Add NAT Rule section rules for the translation of IP addresses for outgoing telegrams are created Example Function Value Meaning Desired priority 1 64 Order number to prioritize the rules beginning with 1 and assigned consecutively Source IP Network 12...

Page 51: ...le applies TCP UDP all OFF Incoming Dest Port 80 Port number of the service e g web server port 80 Outgoing Dest Port 80 Sett the NAT PAT rule Add the rule via ADD and send the rule to the device via SET Example The web server of a TBEN L5 PLC 10 original IP 12 222 2 95 in a plant network WAN 12 222 2 0 is accessed from a PC in the company network LAN 192 168 1 0 via a defined IP ad dress destinat...

Page 52: ...AN Company network Original IP 192 168 1 15 IP address in the LAN via which the TBEN L5 PLC 10 is to be accessed Destination IP 12 222 2 95 IP address of the TBEN L5 PLC 10 in the WAN that is to be accessed via the LAN IP address 192 168 1 15 Destination IP Protocol TCP Defines for which telegrams the rule applies TCP UDP all OFF Incoming Dest Port 80 Port number of the web server Outgoing Dest Po...

Page 53: ...igger responses from connected IGMP capable participants Version 1 A host can join a multicast group Logoff is not imple mented After a timeout the host is deregistered 2 Starting with IGMP version 2 devices can log off from receiving IGMP messages with a leave message Interval s 0 01 1000000 s Query Snooper or transmit interval Querier Time out s 0 01 1000000 s Time after which a device no longer...

Page 54: ...s date and time information from an external NTP server and makes it available to the connected devices Enable time synchronization via NTP server with enable Define NTP time server using the IP address of the server In this example the time server of the TU Berlin with the IP address 130 149 17 21 is used Set the interval for the time query Use SET CONFIG to send changes to the device Fig 49 Webs...

Page 55: ...this is indicated by the entry Nonpersistent Configuration at the bottom of the web server screen Configuration changes are only stored in the device until a device failure or power reset If the configuration is to be accepted as a permanent configuration Activate the configuration via Make current configuration persistent Ò SAVE as perman ent configuration Fig 50 Web server configuration ...

Page 56: ... current configuration to defaults Load saved configuration Select the file with the saved configuration cfg via Upload and apply new configura tion Ò SELECT FILE Write the configuration to the device via APPLY The configuration is not stored perman ently in the device To save the configuration permanently in the device use Make current configuration persistent Ò SAVE as permanent configuration St...

Page 57: ...min password password Insert the USB stick with the file cmd json into the device a The RUN LED flashes 3 green at 1 Hz a The RUN LED flashes green at 0 5 Hz Within 30 seconds hold down the Set button for at least 3 seconds to start the update a The RUN LED turns off a When the RUN LED flashes green 1 Hz the transfer of the configuration to the device is complete Remove the USB stick Compatible US...

Page 58: ...hernet connection established 100 Mbps XF1 XF10 or respectively 1 Gbps XF9 and XF10 Yellow Ethernet connection established 10 Mbps Green flashing Data transfer 100 Mbps XF1 XF10 or respectively 1 Gbps XF9 and XF10 Yellow blinking Data transfer 10 Mbps LED BUS No function LED ERR No function NOTE The flashing pattern of the RUN LED indicates the configuration process when using the USB host functio...

Page 59: ...view The Overview page shows an overview of all Ethernet interfaces of the device the device data name firmware version etc and the current device settings VLAN DHCP routing etc A click on the respective entries opens the corresponding configuration page Fig 52 Web server overview ...

Page 60: ... 2 Monitoring Counter network load monitoring The Counter page shows all sent and received telegrams as well as the calculated network load in percent The values can also be displayed graphically Select the values by double clicking them Use the Graph button to switch to the graphical view Fig 53 Webserver Counter tables ...

Page 61: ...V02 00 2021 11 61 a The values are displayed graphically Fig 54 Webserver Counter graphical representation ...

Page 62: ...ics The cable diagnostics detects cable breaks in the Ethernet line Select the Ethernet ports for which line diagnostics are to be performed Start line diagnostics via START CABLE DIAGNOSTCS a The lines on the selected Ethernet ports are checked a Cable breaks are detected and localized wire by wire Fig 55 Web server cable diagnostics ...

Page 63: ...first check whether ambient interference is present If there is no ambient interference present check the connections of the device for faults If there are no faults there is a device malfunction In this case decommission the device and replace it with a new device of the same type ...

Page 64: ...ned if it is faulty Observe our return acceptance conditions when returning the device to Turck 12 1 Returning devices Returns to Turck can only be accepted if the device has been equipped with a Decontamination declaration enclosed The decontamination declaration can be downloaded from https www turck de en retoure service 6079 php and must be completely filled in and affixed securely and weather...

Page 65: ...12 4 pin D coded Permissible torques n Ethernet n Mounting M6 screws 0 6 Nm 1 5 Nm Isolation voltages V1 to V2 500 V AC V1 V2 to field bus 500 V AC System data Transmission rate XF1 XF8 10 100 Mbps XF9 XF10 10 100 1000 Mbps Web server Integrated Default IP address 192 168 1 254 Mounting Type of mounting Via 2 mounting holes Ø 6 3 mm Mounting distance device to device 50 mm Valid for operation in t...

Page 66: ...use UL only Overvoltage category II Weight 605 g Operating height Max 5000 m Protection class IP65 IP67 IP69K not evaluated by UL Pollution degree 2 MTTF n TBEN L4 SE M2 and TBEN L5 SE M2 82 years acc to SN 29500 Ed 99 20 C n TBEN LL SE M2 81 years acc to SN 29500 Ed 99 20 C Housing material PA6 GF30 Halogen free Yes FCC declaration NOTE This device complies with the limits for a Class A digital d...

Page 67: ...pproval no TÜV 20 ATEX 264795 X ÉII 3 G ÉII 3 D Ex ec IIC T4 Gc Ex tc IIIC T115 C Dc IECEx approval no IECEx TUN 20 0010X Ex ec IIC T4 Gc Ex tc IIIC T115 C Dc Ambient temperature Tamb 25 C 60 C Type designation TBEN L_ SE Supply voltage 24 VDC 10 Input current Imax 9 A total per module Output current Imax 1 5 A per output ...

Page 68: ... S A S 11 rue de Courtalin Bat C Magny Le Hongre F 77703 MARNE LA VALLEE Cedex 4 www turckbanner fr Great Britain TURCK BANNER LIMITED Blenheim House Hurricane Way GB SS11 8YT Wickford Essex www turckbanner co uk India TURCK India Automation Pvt Ltd 401 403 Aurum Avenue Survey No 109 4 Near Cummins Complex Baner Balewadi Link Rd 411045 Pune Maharashtra www turck co in Italy TURCK BANNER S R L Via ...

Page 69: ...turck ru Sweden Turck Sweden Office Fabriksstråket 9 433 76 Jonsered www turck se Singapore TURCK BANNER Singapore Pte Ltd 25 International Business Park 04 75 77 West Wing German Centre 609916 Singapore www turckbanner sg South Africa Turck Banner Pty Ltd Boeing Road East Bedfordview ZA 2007 Johannesburg www turckbanner co za Czech Republic TURCK s r o Na Brne 2065 CZ 500 06 Hradec Králové www tu...

Page 70: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100013016 2021 11 100013016 ...

Reviews: