turck RU40-AP Series Manual Download Page 1

Your Global Automation Partner

IO-Link Parameters – IO-Link Version 1.1

RU40…-AP…

Ultrasonic Sensors

Summary of Contents for RU40-AP Series

Page 1: ...Your Global Automation Partner IO Link Parameters IO Link Version 1 1 RU40 AP Ultrasonic Sensors...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 3: ...d 5 1 3 Other documents 5 2 Information About the Product 6 2 1 Product identification 6 2 2 Manufacturer and service 6 3 Software Supported IO Link parameterization 7 4 IO Link Parameters 8 4 1 Gener...

Page 4: ...Contents 4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com...

Page 5: ...ided WARNING WARNING indicates a dangerous situation with medium risk of death or severe in jury if not avoided CAUTION CAUTION indicates a dangerous situation of medium risk which may result in minor...

Page 6: ...m an der Ruhr Germany Turck supports you with your projects from initial analysis to the commissioning of your applic ation The Turck product database contains software tools for programming configura...

Page 7: ...ent ways n via on request data objects e g IO Link function block close to the control n via tool based engineering using FDT DTM e g PACTware with the use of DTM or the IODD Device parameters on requ...

Page 8: ...eters Parameter Content Vendor ID 317 0x13D Device ID 263170 0x40402 IO Link version 1 1 Bitrate COM2 38 4 kbit s Minimum cycle time 2 ms SIO supported True M Sequence Capability PREOPERATE TYPE_0 wit...

Page 9: ...ata Name Byte Bit offset Bit Length Subindex access supported Data Type Value Description Process Value 0 1 15 True UInteger 0 32767 0 no target 1 muted 2 filtered Switch state output 1 1 0 1 True Boo...

Page 10: ...0x0 True write 0 0 8 UInteger 0 177 System command 75 Far Switch point Teach 76 Near Switchpoint Teach 79 Cancel Teach 128 Device Reset 129 Application Reset 130 Restore Fact ory Settings 160 161 176...

Page 11: ...21 0x15 0 0x0 True read 0 0 128 String Device serial number Firmware Version 23 0x17 0 0x0 True read 0 0 512 String Firmware revision Application Specific Tag 24 0x18 0 0x0 True read write 0 0 32 Str...

Page 12: ...nt Value Teach Flag 59 0x3B 2 0x2 True read 0 4 1 Boolean false true false Not taught or not successful true Successfully taught Teach State 59 0x3B 3 0x3 True read 0 0 4 UInteger 0 7 0 Idle 1 Far swi...

Page 13: ...with additional sensors Synchroniza tion mode Synchronized sensor net work Enable mode Sensor remote enabling Op posed mode Sensor is emitter or receiver 0 Standard Mode 1 Multiplex Mode 2 Synchroniz...

Page 14: ...nally defined temperature 0 Internal 1 External Temperature Value For External Temperature Compensa tion 113 0x71 0 0x0 True read write 0 0 16 Integer 300 850 250 Value of externally define d temperat...

Page 15: ...120 0x78 0 0x0 True read 0 0 16 Integer 300 850 Internally measured value of ambient temperature that is used for compensa tion if internal temperature compensation is selected Signal Strength Indica...

Page 16: ...ore turck com www turck com 4 5 Events Code Type Name Description 30480 Error Short circuit Check installation 35856 Warning Process variable range over run Process data uncertain 36010 Error Storage...

Page 17: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100013986 2019 11 100013986...

Reviews: