Connection to a Siemens Step 7 - usage of the TURCK- example program
D301171 - IO-Link master 1108
4-6
Configuration of the IOLMM (IO-Link master module)
Slot 1 of the modular slave contains the IO-Link master module (IOLMM). The IOLMM serves
as gateway between IO-Link and PROFIBUS-DP. It handles the IO-Link data of the IO-Link
ports for further processing on PROFIBUS.
Parameterization of the IOLMM
The parameters of the IO-Link master module (slot 1) control the communication of the
complete SDPX-IOL4-0001 including all connected devices.
The parameters of slot 1 (IOLMM) have to be set according to the application, see also
,
.
Configuration of the IO-Link ports
The 4 ports of the IO-Link master (slot 2 to slot 5) can be operated either in IO-Link mode or
in SIO mode (see also
The determining factor for the function mode of the ports is their configuration:
General
IO-Link mode:
If the port is to be used in the IO-Link mode, a sensor with a process data width > 0 has
to be selected from the hardware catalog.
IO-Link sensors from TURCK [TURCK … (IOL mode)] are described in the GSD-file of the
IO-Link master and can be comfortably parameterized via GSD-parameters.
Sensors from 3rd-party-manufacturers are represented as generic IO-Link devices with a
maximum number of 32 byte input- and/or output data
.
Note
Please be sure that the parameter
is set to active. Otherwise
the parameterization via GSD done in the following in the hardware configurator will
be ignored.
Figure 16:
GSD-para-
meterization
Note
The selected generic device has to be a device with a process data width
≥
the pro-
cess data width of the connected sensor.