19
[email protected] • www.turck.com • 2015/02
Setting
Teach-in the devices as follows:
Teach to gnD
Teach to u
B
Teach adapter
Press the pushbutton to GND
Press the pushbutton to U
B
Manual bridging (shorting)
Bridge Pin 3 (BU) with Pin 5 (GY)
Bridge Pin1 (BN) with Pin 5 (GY)
Pushbutton on the device
Press pushbutton 1
Press pushbutton 2
Cancel teach-in process: Teach to U
B
for at least 2 s.
The TX1-Q20L60 teach adapter is not supplied with the device and must be ordered additionally. To use the teach
adapter connect it between the sensor and the connection cable.
9.1
Setting via the teach adapter
Selecting the output
➤
➤
Select switching output 1: Press and hold down the pushbutton on the adapter for 2…7 s to GND.
➤
➤
Select output 2: Press and hold down the pushbutton on the adapter to GND for 8…13 s.
Setting a switch point
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Select the switching output.
➤
➤
Position the object for the switch point.
➤
➤
Store switch point: Press and hold down the pushbutton on the adapter for 2…7 s to GND.
➤
➥
The switch point has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Window function – Setting the switching range
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Position the object for switch point 1.
➤
➤
Select the switching output.
➤
➤
Store switch point 1: Press and hold down the pushbutton on the adapter to GND for 8…13 s.
➤
➤
Position the object for switch point 2.
➤
➤
Store switch point 2: Press and hold down the pushbutton on the adapter for 2…7 s to GND.
➤
➥
The switch points have been successfully taught if the green LED flashes for 1.5 s at a frequency of 5 Hz.
Window function – Switching between hysteresis and window
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Position the object at any point in the sensing range.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 8…13 s.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 8…13 s.
➤
➥
The window has been taught successfully if the green LED flashes for 1.5 s at a frequency of 5 Hz.
➤
➥
The hysteresis has been taught successfully if the yellow LED flashes for 1.5 s at a frequency of 5 Hz.
Inverting the output function (NO/NC)
➤
➤
Connect the TX1-Q20L60 teach adapter between the sensor and the connection cable.
➤
➤
Select the switching output.
➤
➤
Press and hold down the pushbutton on the adapter to GND for 14…19 s.
➤
➥
The output function has been inverted successfully to NO if the green LED flashes for 1.5 s at a frequency of
5 Hz.
➤
➥
The output function has been inverted successfully to NC if the yellow LED flashes for 1.5 s at a frequency of
5 Hz.
Ultr
asonic sensors
“H
igh End“