Installing
Special installation instructions
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | [email protected] | www.turck.com
V02.00 | 2022/08 | 13
5.2
Special installation instructions
Only mount Turck sensors from the FS product series using screw-in adapters from the
FAA-… product series.
For devices with a G…
″
process connection: Position one of the two seals (included in the
delivery) between the screw-in adapter and the process connection (e.g. union).
Screw the screw-in adapter onto the process connection (maximum torque of 100 Nm).
Guide the probe rod through the screw-in adapter and hand-tighten the sensor
(M18 × 1.5 coupling nut) with the screw-in adapter.
For a standard flow range (3…300 cm/s): The probe rod can be installed in the medium
independent of the flow direction (range of 360°).
For an extended flow range (1…300 cm/s): Mount the probe rod directed so that the
medium flows toward the prick punch mark, tolerance range of ± 45°.
prick punch mark
A
A
Fig. 10: Mount the probe rod directed correctly
Screw an M18 × 1.5 coupling nut onto the screw-in adapter (maximum torque of 40 Nm).
Optional: For optimum operation and readability, adjust the sensor head within a range
of 340°.
For devices with a G…
″
process connection: After removing and reinstalling the screw-in
adapter, use a new seal (replacement seal included in the delivery).
After removing and reinstalling the sensor, teach in new teach-in values.