Technical features
D301239 1013 - BL67 AIDA PROFINET
4-34
Technology modules
BL67-1RS232
Table 4-24:
Module parame-
ters
A
default
setting
Byte Bit
Parameter
name
Value
–
Meaning
0
3 to 0
Data rate
0000 = 300 bps
0001 = 600 bps
0010 = 1200 bps
0100 = 2400 bps
0101 = 4800 bps
0110 = 9600 bps
A
0111 = 14400 bps
1000 = 19200 bps
1001 = 28800 bps
1010 = 38400 bps
1011 = 57600 bps
1100 = 115200 bps
... reserved
5.4
reserved
-
6
DisableReducedCtrl
Constant setting:
The diagnostic messages are shown in Byte 6
of the process input data (independently from
“Diagnosis").
Byte 6 of the process output data contains 2
bits, with which the receive or transmit buffer
can be cleared.
Byte 7 contains the status or control byte. User
data are represented in Bytes 0 - 5.
7 Diagnosis
0
=
release
A
1 = block
1
0
Stop bits
0 = 1 bit
A
1 = 2 bit
2.1
Parity
00 = none
01 = odd
A
– The parity bit is set so that the total number
of bits (data bits plus parity bit) set to 1 is
odd.
10 = even
– The parity bit is set so that the total number
of bits (data bits plus parity bit) set to 1 is
even.
Summary of Contents for BL67-GW-PN-AC
Page 1: ...USER MANUAL PROFINET AIDA gateway BL67 GW PN AC...
Page 6: ...D301239 1013 BL67 AIDA PROFINET iv...
Page 20: ...PROFINET D301239 1013 BL67 AIDA PROFINET 3 4...
Page 66: ...Technical features D301239 1013 BL67 AIDA PROFINET 4 46...
Page 94: ...Guidelines for station planning D301239 1013 BL67 AIDA PROFINET 6 6...
Page 112: ...Mounting and mounting instructions D301239 1013 BL67 AIDA PROFINET 8 10...
Page 116: ...Appendix D301239 1013 BL67 AIDA PROFINET 9 4...