Setting
Parameters
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | [email protected] | www.turck.com
V01.00 | 2022/09 | 17
8
Parameterizing and configuring
8.1
Parameters
IO-Link object directory — ISDU device parameters: Direct Parameter Page
ISDU
Index
Hex. (dec.)
Sub index Object name
Access
Length
in bytes
Meaning/default value
0x00
(0)
Direct Parameter Page 1
read
only
16
0x03
Min. cycle time
read
only
1
0x05
IO-Link version ID
read
only
1
17
0x08
Vendor ID
read
only
2
ID for Turck:
0x013D
0x09
0x0A
Device ID
read
only
3
E. g.: TBIL-L…-16DXP-AUX:
0xE330…
0x0B
0x0C
IO-Link object directory — ISDU device parameters: Identification
ISDU
Index
Hex.
(dec.)
Object name
Access
Length
in bytes
Meaning/
default value
Comment
0x10
(16)
Vendor
name
read
only
16
Turck
0x11
(17)
Vendor text
read
only
32
www.turck.com
0x12
(18)
Product
name
read
only
32
TBIL-L…-16DXP-AUX
0x13
(19)
Product ID
read
only
16
ID of the device
0x14
(20)
Product text
read
only
32
I/O hub
0x15
(21)
Serial
number
read
only
16
Sequential serial number
0x16
(22)
Hardware ID
read
only
8
Hardware revision of the device, e. g. V1.0
0x17
(23)
Firmware
revision
read
only
16
Firmware revision of the device, e. g. V1.0.7.0
0x18
(24)
Application
Specific Tag
read/
write
32
Default "***"
Field for customer or
application specific
data