IO-Link Parameters

Parameters

12

Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com

4.5

Parameters

Name

Index
(dec.)

Index
(hex.)

Sub-
index 
(dec.)

Sub-
index
(hex.)

Sub-
index 
access
supported

Access Byte.

Bit
Offset

Bit 
length

Data Type Value Default Description

Function 
specific tag

25

0x19

0

0x0

True

read/
write

0.0

256

String

NaN

NaN

***

The parameter
Function 
specific tag
contains the
description of
the function of
a profile
Device within
an application.

Location 
specific tag

26

0x1A 0

0x0

True

read/
write

0.0

256

String

NaN

NaN

***

The parameter
Location 
specific tag
contains the
description of
the location of
a profile
Device within
an application.

Operating
hours counter

72

0x48

0

0x0

True

read

0.0

32

UInteger NaN


NaN

0

Time in hours
during which
the device is
in operation.

Filter

256 0x100 0

0x0

True

read/
write

0.0

2

UInteger 0…1

1

Filter function

0

Slow

1

Well balanced

Center point

258 0x102 0

0x0

True

write 0.0

1

Boolean

false/
true

Sets the cur-
rent position
of the device
as the center
point.

true

Set center
point now

Direction of
rotation

259 0x103 0

0x0

True

read/
write

0.0

8

UInteger 0…4

Direction of
rotation of the
device

0

Clockwise

4

Counterclock-
wise

Perform

260 0x104 1

0x1

True

write 0.0

1

Boolean

false/
true

true

Perform 
selftest now.

false

Summary of Contents for B1N360V-QR20-IOLX3 Series

Page 1: ...Your Global Automation Partner IO Link Parameters IO Link Version 1 1 B1N360V QR20 IOLX3 Inclinometer ...

Page 2: ...2 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Page 3: ...ts 5 1 4 Feedback about these instructions 5 2 Notes on the Product 6 2 1 Product identification 6 2 2 Manufacturer and service 6 3 Software Supported IO Link Parameterization 7 4 IO Link Parameters 8 4 1 General parameters 8 4 2 Process input data 9 4 3 Process output data 9 4 4 Standard parameters 10 4 5 Parameters 12 ...

Page 4: ...Contents 4 Hans Turck GmbH Co KG T 49 208 4952 0 F 49 208 4952 264 more turck com www turck com ...

Page 5: ...rous situation of medium risk which may result in minor or moderate injury if not avoided NOTICE NOTICE indicates a situation which may lead to property damage if not avoided NOTE NOTE indicates tips recommendations and useful information on specific actions and facts The notes simplify your work and help you to avoid additional work u CALL TO ACTION This symbol denotes actions that the user must ...

Page 6: ...m an der Ruhr Germany Turck supports you with your projects from initial analysis to the commissioning of your applic ation The Turck product database contains software tools for programming configuration or commissioning data sheets and CAD files in numerous export formats You can access the product database at the following address www turck de products For further inquiries in Germany contact t...

Page 7: ...ia FDT DTM e g PACTware with the use of DTM or the IODD Device parameters on request data objects Device parameters are exchanged acyclically and on request of the IO Link master The IO Link master always sends a request to the device first then the device responds This applies when the data is written into the device and also when read from the device On request data objects ORDO enable parameter...

Page 8: ...O Link Parameters 4 1 General parameters Parameter Content Vendor ID 317 0x13D Device ID 720901 0xB0005 IO Link version 1 1 Bitrate COM3 Minimum cycle time 1 3 ms SIO supported False M Sequence Capability PREOPERATE TYPE_1_V with 8 octets on request data ISDU supported Block Parameter True Data Storage True ProfileCharacteristic ...

Page 9: ...6 True Integer 18000 18000 Signed 0 35999 Unsigned Process data 2 0 16 True Integer 18000 18000 Signed 0 35999 Unsigned Scale 10 x 1 0 8 True Integer 127 127 Vendor specific 0 0 8 True UInteger 0 3 4 3 Process output data Name Byte Bit offset Bit length Subindex access supported Data Type Value Description Process data output 0 0 8 False UInteger 0 3 ...

Page 10: ...28 Device Reset 129 Application Reset 130 Restore Factory Settings Data Storage Lock 12 0xC 2 0x2 False read write 0 1 1 Boolean false true Device access locks Vendor Name 16 0x10 0 0x0 True read 0 0 5 String Turck Vendor name Vendor Text 17 0x11 0 0x0 True read 0 0 13 String www turck com Additional manufacturer information Product Name 18 0x12 0 0x0 True read 0 0 24 String B1N36 0V QR20 IOLX3 H1...

Page 11: ...t offset Bit length Data Type Value Default Description Process Data Input 40 0x28 0 0x0 True read write 0 0 48 Process DataIn Union Process Data Input 40 0x28 1 0x01 True write 0 0 8 UInteger 0x04 Center point teach function for the Z axis Process Data Output 41 0x29 0 0x0 True write 0 0 8 Process Data OutUnion ...

Page 12: ...ing NaN NaN The parameter Location specific tag contains the description of the location of a profile Device within an application Operating hours counter 72 0x48 0 0x0 True read 0 0 32 UInteger NaN NaN 0 Time in hours during which the device is in operation Filter 256 0x100 0 0x0 True read write 0 0 2 UInteger 0 1 1 Filter function 0 Slow 1 Well balanced Center point 258 0x102 0 0x0 True write 0 ...

Page 13: ...r the Z Axis via the blinking frequency false Off true On Actual temperature 299 0x12B 1 0x1 True read 2 0 8 Integer 127 127 0 Currently measured temperature in C 40 105 C Maximum temperature 299 0x12B 2 0x2 True read 1 0 8 Integer 127 127 0 Maximum measured temperature in C 40 105 C Minimum temperature 299 0x12B 3 0x3 True read 0 0 8 Integer 127 127 0 Minimum measured temperature in C 40 105 C Pr...

Page 14: ...Over 30 subsidiaries and over 60 representations worldwide www turck com 100027854 2021 03 100027854 ...

Reviews: