IO-Link Parameters
Parameters
12
Hans Turck GmbH & Co. KG | T +49 208 4952-0 | F +49 208 4952-264 | [email protected] | www.turck.com
4.5
Parameters
Name
Index
(dec.)
Index
(hex.)
Sub-
index
(dec.)
Sub-
index
(hex.)
Sub-
index
access
supported
Access Byte.
Bit
Offset
Bit
length
Data Type Value Default Description
Function
specific tag
25
0x19
0
0x0
True
read/
write
0.0
256
String
NaN
…
NaN
***
The parameter
Function
specific tag
contains the
description of
the function of
a profile
Device within
an application.
Location
specific tag
26
0x1A 0
0x0
True
read/
write
0.0
256
String
NaN
…
NaN
***
The parameter
Location
specific tag
contains the
description of
the location of
a profile
Device within
an application.
Operating
hours counter
72
0x48
0
0x0
True
read
0.0
32
UInteger NaN
…
NaN
0
Time in hours
during which
the device is
in operation.
Filter
256 0x100 0
0x0
True
read/
write
0.0
2
UInteger 0…1
1
Filter function
0
Slow
1
Well balanced
Center point
258 0x102 0
0x0
True
write 0.0
1
Boolean
false/
true
Sets the cur-
rent position
of the device
as the center
point.
true
Set center
point now
Direction of
rotation
259 0x103 0
0x0
True
read/
write
0.0
8
UInteger 0…4
Direction of
rotation of the
device
0
Clockwise
4
Counterclock-
wise
Perform
260 0x104 1
0x1
True
write 0.0
1
Boolean
false/
true
true
Perform
selftest now.
false