Page 1: ......
Page 2: ...2 2 PRODUCT INTRODUCTIONS 6 3 VERIFY CONTENTS 9 4 GATHER TOOLS 11 4 PLAN THE MOUNTING 12 5 MOUNT THE CHARGING STATION 13 6 WIRE THE CIRCUIT 14 7 OPERATE YOUR DEVICE 15 8 LIGHT CODES 19 9 SMART APP GUIDE OPTIONAL 20 10 FCC STATEMENT 20 11 WARRANTY AND MAINTENANCE 21 ...
Page 3: ...of electric shock WARNING This device should be supervised when used around children WARNING This device must be grounded WARNING To avoid a risk of fire or electric shock do not use this device with an extension cord WARNING The suitability of the use of flexible cord in accordance with CE code part I rule 4 012 is to be determined by the local inspection authority WARNING To reduce the risk of f...
Page 4: ...ectric Code ANSI NFPA70 CAUTION The device shall be mounted at height between 2 feet 600 mm and 4 feet 1200 mm from ground CAUTION Please keep the charger in a clean area with low humidity Not recommended to be installed in coastal environments with high humidity or high dust 1 3 Daily Maintenance CAUTION Avoid moisture or water in the charger If there is water or moisture ingress in the charger i...
Page 5: ...rique AVERTISSEMENT Cet appareil doit être surveillé lorsqu il est utilisé à proximité d enfants AVERTISSEMENT Cet appareil doit être mis à la terre AVERTISSEMENT Pour éviter tout risque d incendie ou de choc électrique n utilisez pas cet appareil avec une rallonge électrique AVERTISSEMENT L adéquation de l utilisation du cordon flexible conformément au code ce partie i règle 4 012 doit être déter...
Page 6: ...lectricité ANSI NFPA70 MISE EN GARDE Cet appareil doit être monté à une hauteur entre 600 mm 2 pieds et 1200 mm 4 pieds du sol MISE EN GARDE Veuillez conserver le chargeur dans un endroit propre et peu humide Il n est pas recommandé de l installer dans des environnements côtiers à forte humidité ou à forte poussière 1 3 Entretien Quotidien MISE EN GARDE Évitez l humidité ou l eau dans le chargeur ...
Page 7: ...ations and away from dangerous substances such as flammable gases and corrosive materials 3 1 Basic Interface LED Light Indication SAE J1772 AC Charging Connector Rear Notch AC Power Cable LAN Cable Inlet Charging Cable 3 2 Basic Dimension Enclosure Wall Mounted Bracket ront iew Left iew Bottom iew 3 15 4 Φ0 35 2 36 ...
Page 8: ... Control Pilot Fault Protection Output Interface SAE J1772 AC Charging Connector Storage Temperature 40 F to 158 F Operation Temperature 22 F to 122 F Relative Operation Humidity 95 RH Maximum Relative Storage Humidity 95 RH Maximum RFID Authentication LAN Version Wi Fi Version RJ45 Cable Inlet 1 10M 100M Base T Wi Fi Function 2 802 11 b g n Cable Length 18ft Protection Level Type 3 Installation T...
Page 9: ...ectric Vehicle EV Supply Circuits Particular Requirements for Protection Devices for Use in Charging Systems UL 2251 Plugs Receptacles and Couplers for Electric Vehicles UL 62 Flexible Cords and Cables UL 991 Tests for Safety Related Controls Employing Solid State Devices UL 1998 Software in Programmable Components NFPA 70 Article 625 National Electrical Code Electric Vehicle Charging System UL 84...
Page 10: ...USER MANUAL 9 3 Verify Contents Check the box to ensure you have this installation guide and these parts 4 5 6 7 2 3 8 9 10 11 12 13 1 ...
Page 11: ...n Wrench 1 For tightening M5 Screws 8 M5 Anti Theft Countersunk Head Screws 4 For securing the Plug Holster to the Holster Bracket 9 M6 Anti Theft Hexagonal Expansion Screws 4 For installing the Holster Bracket to the wall structure 10 Plug Holster 1 For allowing the plugs to be neatly and safely stored when not in use 11 Holster Bracket 1 For mounting the Plug Holster to the wall structure 12 Cor...
Page 12: ...er or digital multi meter for measuring AC voltage at the installation site 4 Level 5 Pencil or marker 6 Drill 7 The inserting cable should meet the best waterproof performance It is recommended to use 3 core 7AWG cable XLPE or equivalent cable to pull the cable from the distribution box Note The above tools are very important please gather them all 1 2 3 4 5 6 ...
Page 13: ... location with electrical capacity I Ensure the owner has chosen a mounting location that allows the charging cable to reach the car s charging port while still providing slack II The device must be anchored into mounting such as 2 x 4 stud or a solid wall III The device shall be mounted at height between 2 feet 600 mm and 4 feet 1200 mm from ground STEP 2 Drill 8 Screw Holes with a diameter of 0 ...
Page 14: ...downward STEP 4 Use 2 different sets 8 pcs in total of Hexagonal Expansion Screws to secure the wall mounted bracket and holster bracket use anti theft hexagonal expansion screws on the wall Then level the brackets STEP 5 Align the rear notch of charger with the wall mounted bracket and fit the screw holes of the right and left side STEP 6 Tighten two M5 anti theft screws to complete the installat...
Page 15: ...duct is properly grounded Do not modify the plug provided with the product if it doesn t fit the outlet have a proper outlet installed by a qualified electrician CAUTION Use appropriate protection when connecting to the main power distribution cable STEP 7 For safe use of electricity please set circuit breaker protection in the input part of E Charger The wiring is not complicated just need to fol...
Page 16: ... the enclosure If the case is damaged please contact a professional technician CAUTION Do not put heavy objects on the charger to avoid danger 7 1 Operating Steps with Plug and Charge STEP 1 Standby Mode After being powered on the lights will be all on blue light READY green light CHARGE and red light AULT Then the blue light READY is constantly on in standby mode READY ...
Page 17: ...plug the vehicle connector again If red light is still on please refer to Error and Warning Messages STEP 4 Charging finished When the charging is finished the green light CHARGE is constantly on please press the button on connector and pull out the charging connector STEP 5 Re plug the charging connector when you finish the charging process please re plug the charging connector back to the holste...
Page 18: ...n blue light READY green light CHARGE and red light AULT all on The blue light READY is constantly on when in standby mode STEP 2 Swipe the RFID Card Please plug the charging connector into the vehicle charging inlet Swipe the R ID card first and plug in the charging connector within 120 seconds otherwise you need to swipe the R ID card again READY ...
Page 19: ...still on please refer to Error and Warning Messages STEP 4 Charging finished When the charging is finished the green light CHARGE is constantly on please press the button on connector and pull out the charging connector STEP 5 Re plug the charging connector when you finish the charging process please re plug the charging connector back to the holster you will hear a click sound CHARING ...
Page 20: ... sec pause Auto Recover OTP 4 flashes followed by 3 sec pause Auto Recover RCD Abnormal 5 flashes followed by 3 sec pause Auto Recover Ground Fault 6 flashes followed by 3 sec pause Auto Recover Control Pilot Fault Flicker Auto Recover MCU Self Test Fail Constantly Bright Contact Customer Service RCD Self Test Fail Constantly Bright Contact Customer Service Relay Self Test Fail Constantly Bright C...
Page 21: ... of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a reside...
Page 22: ...owing the product service instruction for use maintenance and storage 5 Damage or malfunction caused by external object entering 6 Unauthorized repair disassembly or modification 7 Damage caused by force majeure such as lightning excessive voltage earthquake fire flood etc 8 Malfunction and damage caused by other unavoidable external factors Malfunction and damage caused by improper use of equipme...