background image

 

 

 

 

3.

 

INSTALLATION

 

3.1. Component list 

 

 

 

 
 

1

4

8

9

Description

Qty

1

Hibrid Inventer HIS Series

1

2 Stainless steel mounting screws M6*12

2

3

Stainless steel expansion bolts M8*80

4

4

User Manual

1

5

WiFi Plug

1

6

Current transformer (Optional)

1

7

Battery sensor

1

8

L-type Hexagon wrench

1

9

Wall mounting bracket

1

Summary of Contents for HIS 5000/48

Page 1: ...https www turbo e com Instruction manual Hybrid Series 48V 5 0 HIS 5000 48 ...

Page 2: ... sensor connection 12 3 4 2 CT connection 12 3 5 AC Input Output connection 13 3 6 PV connection 13 3 6 1 PV Module selection 14 3 7 Grounding connection 14 3 8 Wi Fi connection 15 3 9 Inverter global connection 15 3 10 Single phase parallel connection diagram 16 3 11 Three phase parallel Inverter 17 4 OPERATION 17 4 1 POWER ON OFF 17 4 2 Operation and display panel 18 5 LCD DISPLAY 18 5 1 Main sc...

Page 3: ...tup Menu 24 5 8 Grid Setup Menu 24 5 9 GEN PORT use Setup Menu 25 5 10 Advanced Function Setup Menu 26 5 11 Device Info Setup Menu 26 6 MODES 27 7 FAULT INFORMATION AND PROCESSING 29 8 LIMITATION OF LIABILITY 31 9 DATASHEET 32 ...

Page 4: ... this inverter please follow required specification to select appropriate cable size It is very important to correctly operate this inverter Please strictly follow installation procedure when you want to disconnect AC or DC terminals Please refer to Installation section of this manual for the details Grounding instructions This inverter must be connected to a permanent grounded wiring system Be su...

Page 5: ...ttons 4 Battery input connectors 5 BMS 485 Port 6 CAN Port 7 DRMs Port 8 Parallel connection port 9 Multifunction port 10 RS 485 Port 11 Gen Port 12 Back Up Port 13 Grid 14 Power On Off button 15 DC Switch 16 2 PV inputs 2 MPPTs 17 Battery 18 Temperature sensor 19 Wi Fi interface 20 Fan ...

Page 6: ...s by LCD setting Configurable AC Solar Generator Charger priority by LCD setting Compatible with grid voltage or generator power Overload over temperature short circuit protection Smart battery charger design for optimized battery performance With export 0 function prevent excess power flow to grid Wi Fi monitoring of the inverter Two photovoltaic inputs with two maximum power trackers MPPT Possib...

Page 7: ...cription Qty 1 Hibrid Inventer HIS Series 1 2 Stainless steel mounting screws M6 12 2 3 Stainless steel expansion bolts M8 80 4 4 User Manual 1 5 WiFi Plug 1 6 Current transformer Optional 1 7 Battery sensor 1 8 L type Hexagon wrench 1 9 Wall mounting bracket 1 ...

Page 8: ...sure snow laying up during installation and operation Before connecting all wires please take off the metal cover by removing screws as shown below Consider the following considerations before selecting the installation location Please select a vertical wall with load bearing capacity for installation suitable for installation on concrete or other non flammable surfaces Installation is shown below...

Page 9: ...iate wall according to the bolt positions on the mounting shelves and mark the holes On the brick wall the installation must be suitable for the expansion bolt installation 2 Ensure that the position of the installation holes on the wall A B C D are the same position of the install plate and the mounting level is guaranteed 3 Hang the inverter to the top of the mounting rack and then use the M4 sc...

Page 10: ... fuse or circuit breaker size Model Cable Cable mm 2 Torque value max 5KW 3AWG 25 5 2Nm Please follow the steps below to implement battery connection 1 Please choose a suitable battery cable with correct connector which can well fit into the battery terminals 2 Use a suitable screwdriver to unscrew the bolts and fit the battery connectors in then fasten the bolt by the screwdriver Make sure the bo...

Page 11: ...11 3 4 Multifunction port connection ...

Page 12: ...12 3 4 1 Temperature sensor connection 3 4 2 CT connection ...

Page 13: ...terminal screws Make sure the connection is complete 3 Then insert AC output wires according to polarities indicated on the terminal block and tighten terminal Be sure to connect corresponding N wires and PE wires to related terminals as well 4 Make sure the wires are securely connected 5 Appliances such as air conditioner are required at least 2 3 minutes to restart because it is necessary to hav...

Page 14: ... parameters 1 Open circuit Voltage Voc of PV modules do not exceed max PV array open circuit voltage of inverter 2 Open circuit Voltage Voc of PV modules should be higher than min start voltage Inverter Model 5kW PV Input Voltage V 370V 100V 500V PV Array MPPT Voltage Range MPPT 125Vdc 425Vdc No of MPP Trackers 2 No of strings per MPP Tracker 1 1 3 7 Grounding connection Ground cable shall be conn...

Page 15: ...15 3 8 Wi Fi connection For the configuration of Wi Fi Plug please refer to illustrations of the Wi Fi Plug 3 9 Inverter global connection Arrow pointing to inverter ...

Page 16: ...16 3 10 Single phase parallel connection diagram DC Breaker 150 A AC Grid Port Breaker 40 A AC Back Up Breaker 40 A AC Breaker depends on house loads Arrow pointing to inverter ...

Page 17: ...e case to turn on the unit When the system is not battery connected but connected to either PV or grid and ON OFF button is switched off LCD will still light up Display will show OFF In these conditions when switch on ON OFF button and select NO battery system can still work DC Breaker 150 A AC Grid Port Breaker 40 A AC Back Up Breaker 40 A AC Breaker depends on house loads Arrow pointing to inver...

Page 18: ...cator Messages DC Green led fixed light PV Connection normal AC Green led fixed light Grid connection normal Normal Green led fixed light Inverter operating normal Alarm Red led fixed light Malfunction or warning Function Key Description Esc To exit setting mode Up To go to previous selection Down To go to next selection Enter To confirm selection 5 LCD DISPLAY 5 1 Main screen The LCD is touchscre...

Page 19: ...ssible to enter in the system setup screen which includes Basic Setup Battery Setup Grid Setup System Work Mode Generator port use Advanced function and Li Batt info 4 The main screen shows the system information including Solar Grid Load and Battery It also displays the energy flow direction by arrows When the power is high the color on the panels will change from green to red PV power and Load p...

Page 20: ...20 5 2 Information from Main Menu ...

Page 21: ...rid Solar power curve for daily monthly yearly and total can be roughly checked on the LCD For more accuracy in power generation please check on the monitoring system Click the up and down arrow to check power curve of different period ...

Page 22: ...22 5 4 System Setup Menu 5 5 Basic Setup Menu 5 6 Battery Setup Menu ...

Page 23: ...23 ...

Page 24: ...ion with Bat Sol BU Back Up Mode Battery is not discharged to cover demand CH Charge Mode Battery charge mode Enable Habilita el sistema de trabajo por periodos horarios GPS Grid Peak Shaving Establece el límite de potencia a tomar de Por periodo horario SOC2 Reserva de batería que nunca se utiliza SOC1 Reserva de batería para garantizar el cumplimiento del Lim Potencia a tomar de la red Start End...

Page 25: ...25 5 9 GEN PORT use Setup Menu ...

Page 26: ...26 5 10 Advanced Function Setup Menu 5 11 Device Info Setup Menu Parallel inverter connection review section 3 10 y 3 11 ...

Page 27: ...27 6 MODES Mode I Basic Mode II With Microturbine Mode III With Generator ...

Page 28: ...With On Grid Inverter The 1st priority power of the system is always the PV power then 2nd and 3rd priority power will be the battery bank or grid according to the settings The last power backup will be the Generator if it is available ...

Page 29: ...r local dealer or service center You need to have the following information 1 Inverter serial number 2 Distributor or service center of the inverter 3 On grid power generation date 4 The problem description including the fault code and indicator status displayed on the LCD is as detailed as possible 5 Your contact information In order to give you a clearer understanding of the inverter s fault inf...

Page 30: ...30 ...

Page 31: ...age caused by incorrect use or operation Damage caused by insufficient ventilation of equipment Damage caused by failure to comply with applicable safety standards or regulations Damage caused by natural disasters or force majeure e g floods lightning overvoltage storms fires etc In addition normal wear or any other failure will not affect the basic operation of the product Any external scratches ...

Page 32: ...Input Current A 13A 13A NºMPPTs 2 Strings per MPPT 1 1 AC Output Data Nominal Power W 5000W Max Power W 5500W Peak Power Offgrid 2 of rated power 10 S Back Up max Power W 5000W Nominal Output AC Current A 21 7A Max AC Current A 25A Peak Current A 35A Power Factor 0 8 1 Output Frequency and Voltage 50 60Hz 220 230 240VCA single phase Grid Type Single Phase Current harmonic distortion THD 3 Linear l...

Page 33: ...cations Grid Regulation VDE 0126 AS4777 NRS2017 G98 G99 IEC61683 IEC 62116 IEC 61727 Safety Regulation IEC62109 1 IEC62109 2 EMC EN61000 6 1 EN61000 6 3 General Data Operating Temperature Range ºC 25 a 60 ºC 45 ºC Derating Cooling Fan Noise dB 30 Communication with BMS RS485 CAN Weight kg 20 5 Size mm 580 x 330 x 232 Protection Degree IP65 Installation Style Wall Warranty 5 years ...

Reviews: