Turbo Air TSF-35SD Installation And Operation Manual Download Page 1

Turbo Air Speed up the Pace of Innovation

CAUTION!

PLEASE KEEP POWER

SWITCH ON BEFORE

OPERATING THIS EQUIPMENT

Full Stainless Steel Interior and Exterior

www.turboairinc.com

SOLID DOOR
REFRIGERATOR

TSR-23SD*
TSR-35SD
TSR-49SD
TSR-72SD

SOLID DOOR
FREEZER

TSF-23SD
TSF-35SD
TSF-49SD
TSF-72SD

Refrigerator
Freezer
Installation and Operation Manual

Please read this manual completely before attempting to install or operate this equipment!

Summary of Contents for TSF-35SD

Page 1: ...tainless Steel Interior and Exterior www turboairinc com SOLID DOOR REFRIGERATOR TSR 23SD TSR 35SD TSR 49SD TSR 72SD SOLID DOOR FREEZER TSF 23SD TSF 35SD TSF 49SD TSF 72SD Refrigerator Freezer Install...

Page 2: ...5V 60Hz R 134a 9A 357lbs TSR 49SD 1 3 115V 60Hz R 134a 9 2A 427lbs TSR 72SD 1 2 115V 60Hz R 134a 11 3A 602lbs MODEL COMP H P V Hz REFRIGERANT AMPS WEIGHT TSF 23SD 1 2 115V 60Hz R 134a 7 8A 293lbs TSF...

Page 3: ...contents 3 DO NOT PLACE NEAR HEAT Be sure to avoid hot corners and locations near stoves High ambient temperature will make much lower cooling efficiency 4 INDOOR USAGE ONLY Be sure to install this un...

Page 4: ...quently to maintain proper sealing 4 CHECK AFTER CLEANING Check the unit again for safety Check that the unit is operating properly 1 POWER CORD Be sure that the power cord is connected to the proper...

Page 5: ...e setting is No 5 3 The compressor is automatically cycled by the electronic controller PCB D Sensor 4 The Defrost cycle is automatically controlled by the R sensor and the PCB 5 Set level toward 1 fo...

Page 6: ...GERATOR 9 TEMPERATURE T C 8 7 6 5 4 3 2 1 FAN DOOR TURBO COOLING TEMPERATURE F TEMP SETTING TURBO COOLING FAN RUNNING DOOR OPENING TURBO COOLING BUTTON TEMP CONTROL BUTTON SEE TO PAGE 7 INNER TEMP SEE...

Page 7: ...de the compressor will return to the normal operation 3 During the Turbo Cooling mode works the temperature Up Down button will not affect the compressor s operation 1 By pushing the up down button yo...

Page 8: ...will be turned on 2 Evaporator fan motor is activated when the door both doors for TSR 49SD all three doors for TSR 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 I...

Page 9: ...B F Sensor 4 The Defrost cycle is automatically controlled by the D sensor and the PCB 5 Set level toward 1 for higher temperatures and toward 9 for lower temperatures 6 The interior light is activate...

Page 10: ...ER 9 TEMPERATURE D F 8 7 6 5 4 3 2 1 FAN DOOR MANUAL DEFROST TEMPERATURE F TEMP SETTING MANUAL DEFROST FAN RUNNING DOOR OPENING MANUAL DEFROST BUTTON TEMP CONTROL BUTTON SEE TO PAGE 11 INNER TEMP SEE...

Page 11: ...lighted higher level numbers 1 The electronic defrost controller is set at the factory to provide a defrost cycle every 6 hours 4 times per a day 2 If it is necessary to change the intervals of defros...

Page 12: ...be turned on 2 Evaporator fan motor is activated when the door both doors for TSF 49SD all three doors for TSF 72SD is closed 1 If any door is opened door opening indicator will be turned on 2 In cas...

Page 13: ...tly The back side of the unit is too close to the wall The tray is not in the correct position High moisture air can produce dewdrops during rainy season The door is opened too frequently or left open...

Page 14: ...fter shipment from manufacturer Compressors determined by Turbo air have been defective within this extended time period will at Turbo air s option be either repaired or replaced with a compressor or...

Page 15: ...suse accident damage during transit or installation fire flood or an Act of God 4 NO IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THERE ARE NO OTHER WARRANTIES EXPRESS IMPLI...

Page 16: ...lubricant The polyol ester lubricant has rapid moisture absorbing qualities 2 Drier replacement is very important and must be changed when a system is opened for servicing A620 copper drier or better...

Reviews: