background image

User/Installation Instructions for Radio Smoke Detector 
Model Number: 67005/94

 

 

Brief detector presentation 

-  Battery powered radio smoke detector using the scattered light 

method 

-  Early and reliable fire detection through precise adjustment of the 

release characteristics 

-  Outstanding operating safety by intelligent analysis of the  
     measuring chamber signal 
- Provides 

precise smoke detection 

-  Reduces false alarms due to its high performance measuring 

chamber 

-  Automatic self-test of the complete electronic 
-  Powerful alarm signal of more than 85 dB(A) in case of fire 
-  Operating temperature range –10°C up to +60°C 
-  Wireless linking to Tunstall emergency equipment, via 869MHz 

European Social Alarm Frequency 

-  Typical radio frequency range 25-50 metres 
-  Licensed for detection and alarming in recreation vehicle and buses 
-  The pack includes the detector base, battery, screws and anchors 

 

Safety instructions 

-  The smoke detector generates a powerful and 

shrill noise, which can be harmful to your ears. 
Keep at least a 50 cm distance from the detector 
while performing the function test. 

-  Never use rechargeable batteries, or main 

supply circuits for power supply. This could cause malfunctioning or 
early breakdown of the detector.  

-  Never paint the smoke detector. 
-  Please note: Smoke detectors will always identify the smoke of a 

fire. They will not identify the flame itself. 

-  Smoke detectors are not able to extinguish any fire. In case of 

alarm evacuate the building and call the fire service. 

-  The smoke detector is capable to survey only a defined zone 

around its own position. For optimum protection, ensure that a 
sufficient number of detectors are installed in the area to be 
monitored. 

-  Persons under the influence of alcohol or drugs may have difficulty 

hearing the alarm. 

 

Attention! 

Danger of explosion, during incorrect fitting of the battery. 
Only exchange for the same or similar type of battery. 

 

Place of installation 

The smoke detector performs best when installed on the ceiling in the 
centre of the room. If this is not possible, ensure the detector is at least 
50 cm from the wall. 

 

To be sure that you are woken up by the smoke alarm at night, 
detectors should be placed in all bedrooms to provide minimum pro-
tection. In houses with several floors one smoke detector should be 
placed in the hallway of each floor. 

 

 

Brief detector presentation 

 

Unsuitable places for installation 

To avoid false alarms and malfunctions, never install the smoke detector: 

 

-  inside rooms where heavy vapour, dust or smoke develop under 

regular conditions (bath, kitchen) 

-  near to fireplaces and open fires 
-  near to ventilation systems. The flow of air may deviate the smoke 

so it will never reach the detector 

-  near to neon lamps and energy saving lamps. The starter may 

cause false alarms by electric fields that arise when turning on the 
lamp (minimum distance: 50 cm) 

-  in edges – for example house gables -  in such areas smoke free 

air can accumulate and the identification of fire is hindered 

-  inside rooms with temperatures beneath -10°C or above +60°C 

Installation 

I. 

Fix base (1) using the enclosed assembling parts (2). Do not 
allow the detectors to get dirty through occurring bore dust. 
Do not use countersunk head bolts.  

 

II. 

Connect the 9V lithium battery with the battery clip and in-
sert the battery in the battery tray. 

 

III. 

Place the smoke detector (3) in the base and lock it by turn-
ing it gently clockwise. 

 

IV. 

Proceed to the function test (see chapter “Function test“). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

Note II: The smoke detector will not engage inside the base 

without the battery inserted.

 

Enhanced protection 

Minimum protection 

 

2

 

Minimum protection 

1

Optimal protection 

 

Equipment with restrictions

3

 

D6707263A 

 

Page 1 of 2 