7
Step 2
• If the Right head is not at the same height, we must
loosen (a quarter of a turn) the four screws that are on the
back of the head (Allen key 2,5)
Step 1
• Access the web interface of the machine
• In File Manager / Macros / Height Calibration select DART_Left Height
• Calibrate the base to the desired height
• Now click on Height DART_Right
Step 3
• Once the four screws are loosened, we will use the central
screw to raise or lower our head, once we have it at the
correct height we will tighten the 4 screws that we loosened in
the previous step
Step 4
• After tightening the 4 screws we will check that they are at the same height by alternating the macros Height DART_Left and
Height DART_Right
• If they are not at the same height, repeat steps 2 and 3
• You can use a gauge or a sheet of paper if it is more comfortable for you.
• Remember that to carry out this process the tips must be clean
• Make this check if you change tips