Tufner 8000 REPEL User Manual Download Page 10

8000 REPEL

 Digital Weight Indicator User Manual 

10 

3.

Place the object to be weighed on the scale’s platter and allow the weight in-

dication to stabilize.
The reading shown is the net value of the applied load

4.

If necessary, toggle between the gross weight and the net weight by pressing
the NET/GROSS key

5.

Press the TARE key again to clear the tare value and return to gross weighing
mode

4.3 Piece Counting 

IMPORTANT NOTE:

 The piece counting function cannot be used in commercial (NTEP) 

applications.

 

 

This mode of operation is enabled by setting F30 to 

“3” in the

 Setup Menu (see sepa-

rate installer’s guide for more information).

 This mode is used to indicate the number 

of pieces of an item you have placed on the scale’s platform and is accessed by press-

ing the UNITS key. To ensure accuracy, the parts you are counting must be consistent 
in weight. 

The indicator uses the sampling method to determine the average piece weight (APW) 
of the items you wish to count. When sampling items, always count the parts in your 
hand and place them on the platform all at once. If the APW of the items is too light or 
the total weight of the sample is too light, accuracy cannot be guaranteed. You will get 
an error message, but piece counting will still be allowed. This indicator does not retain 
the piece weight when powered down. 

1. If the items you will be counting require a container, you must first tare the con-

tainer off by pressing the TARE key.

NOTE:

 The TARE key is inoperative when in sampling mode.

2.

Press the UNITS key until “5   0” is indicated on the display. If the scree

n does not

show “5   0”, press the ZERO key once. The indicator is prompting you to place five

identical items on the platform.

NOTE:

 If you wish to change the sample number, simply press the UNITS key re-

peatedly until the desired sample number appears. Available choices are 5, 10, 20,
50 and 100. If you continue to push the UNITS key, the indicator will resort back to
weighing mode and you must start again from Step 2.

3. Place the sample items on the platform all at once and allow the weight indication

to stabilize. Once this is done, the zero indicated after the sample number will

change to a “–“. For example, “5   –“.

4. Press the NET/GROSS key to take the sample. If the sample size is large enough, the

indicator now displays the number of pie

ces on the platform and the “PCS” annun-

ciator is lit. If not, the indicator briefly displays “Lo” and automatically increments

Summary of Contents for 8000 REPEL

Page 1: ...8000 REPEL Digital Weight Indicator User Manual V1 6 TUFNER WEIGHING SYSTEMS 9030 Bridgeport Place Rancho Cucamonga CA 91730 Main 800 810 2965 Fax 888 502 8997...

Page 2: ...2 4 Operation TI 500 RFTM 4 2 5 Replacing the batteries TI 500 RFTM 5 2 6 Optional rechargeable battery information 5 3 DISPLAY KEYPAD DETAILS 7 4 ADVANCED OPERATION 9 4 1 Hold operation 9 4 2 NET we...

Page 3: ...ause damage Routine maintenance Harsh abrasives solvents scouring cleaners and alkaline cleaning solutions should not be used especially on the display window The outside of the product may be wiped d...

Page 4: ...hing it is necessary to check if the scale is unloaded and indicating zero weight in the desired unit of measure for example lb for pounds If the indicator is not displaying the desired unit of measur...

Page 5: ...eries TI 500 RFTM An optional cylindrical battery holder is available which requires 4 C cell alkaline bat teries 1 Turn the TI 500 RFTM OFF Press the RED button 2 Locate the metal battery cylinder 3...

Page 6: ...charged the Low Battery Indicator will start blinking in the lower left hand corner of the display The indicator may be used for an additional 2 minutes before it automatically powers down It is imper...

Page 7: ...he sys tem P Indicates that the indicator is in PEAK HOLD mode lb Indicates that the unit of the displayed weight is in pounds kg Indicates that the unit of the displayed weight is in kilograms g Indi...

Page 8: ...Gross weight 2 The scale is not in motion 3 The scale is not in overload see error codes Net Gross This key toggles the indicator between Gross weight and Net weight provided that a Tare weight has fi...

Page 9: ...essed again If the weight of the object on the scale changes by the F36 setting e g 10 then the sale unlocks the held reading and relocks onto the new weight This occurs during increasing weight value...

Page 10: ...total weight of the sample is too light accuracy cannot be guaranteed You will get an error message but piece counting will still be allowed This indicator does not retain the piece weight when powere...

Page 11: ...esting the breaking point of a part or assembly The 8000 REPEL records both positive and negative peak weights 1 Push the UNITS key to active peak hold mode the P annunciator turns ON 2 Apply force to...

Page 12: ...n the total is reset to zero but not printed If no key is pressed during this period then the subtotal stays in memory and the system returns to the weighing mode 4 6 Printer If the weighing system ha...

Page 13: ...of the flashing digit 10 After entering the exact value press the NET GROSS key to save the value The screen displays n _xx where xx is the current minute e g 55 One digit will be flashing 11 Use the...

Page 14: ...rms then this mode re quires an optional digital I O board Use the A1 25 menu to set the logic of the out puts Optional Digital I O 3 out 1 in Logic level only i e external relays are required to driv...

Page 15: ...of the flashing digit 5 After entering the exact value press the NET GROSS key to save the value The screen displays SET briefly The high low weight values are activated and the display returns to the...

Page 16: ...not found ensure that it is powered ON or move it closer to the digital in dicator WIRELESS SYSTEMS ONLY TI 500 RFTM 1 batteries have been depleted and need to be replaced WIRELESS SYSTEMS ONLY TI 50...

Page 17: ...olycarbonate enclosure rated for IP69 1 0 7 digit LCD w LED backlight optional reverse LCD also available Operating temperature 4 F to 104 F 20 C to 40 C Internal connection port for optional printer...

Page 18: ...and platform or within platform with multiple load cells cabled configuration only Load cell damaged on platform Internal fault with indicator call Tufner Tech Support Scale turns off on its own The i...

Page 19: ......

Reviews: