background image

 

 

RZ5/RZ5D/RZ5P/RZ6 Processor 

Operator’s Manual 

 
 
 
 

 
 
 
 
 

 
 

 
 
 
 
 

 
 
 
 
 

 

 

Summary of Contents for RZ5

Page 1: ...RZ5 RZ5D RZ5P RZ6 Processor Operator s Manual ...

Page 2: ...d as is and is subject to being changed without notice TDT shall not be liable for errors or damages in connection with the furnishing use or performance of this document or of any information contained herein The latest versions of TDT documents are always online at www tdt com support htm A CAUTION informs users when failure to take or avoid a specified action could result in damage to the produ...

Page 3: ...r email support tdt com Using the RZ5 RZ5D RZ5P RZ6 Processor Device This manual provides the directions necessary for powering the Processor on and off as well as its communications functionality and User Interface features Refer to the System 3 Manual provided by TDT for specific instructions on how to program the RZ5 RZ5D RZ5P or RZ6 Processor device Applying Power to the RZ5 RZ5D RZ5P RZ6 CAUT...

Page 4: ... panel The connectors on the fiber optic pair used for PC communication are color coded for correct wiring CAUTION The fiber optic cables have raised keys on one side of the connector There are also keyway notches on the inside of the connector on the RZ5 RZ5D RZ5P RZ6 communications interface module to avoid damage to the interface and cables the fiber optic cable should be oriented so that the k...

Page 5: ...ptical PC interface the preamplifier ports and system I O The Mode button allows the user to cycle between information Press and hold the mode button to automatically cycle through each display Refer to the RZ5 RZ5D RZ5P or RZ6 section of the System 3 Manual for more information Input and Output Ports CAUTION The input and output ports located on the front and back panels of the RZ5 RZ5D RZ5P RZ6 ...

Page 6: ...WARNINGS Read the following warnings prior to operation If the device is damaged or fails to operate as expected disconnect the power cord and contact TDT support immediately The mains disconnect for the device is the power cord To completely disconnect power to the device the power cord must be disconnected Position the device to ensure the power cord is readily accessible after installation and ...

Page 7: ...cts into the fan This may result in injury or damage to the device If the protective screen becomes damaged contact TDT for assistance Do not attempt to store this device where it may be exposed to prolonged periods of excessive sunlight high temperatures high humidity or condensation If exposed to such conditions the device may no longer work properly and its specifications may no longer be satis...

Page 8: ...ops free gently slide the fuse plate and housing out of the power supply 4 The housing contains two fuses Replace the defective broken fuse s with a new 5 x 20mm 250V 1 6A rated slow blow fuse by gently pushing the end of the fuse into the fuse housing 5 Push the fuse housing back into the power supply and press gently until the clip clicks into place Cleaning the Processor Device To clean the dev...

Page 9: ...re information Chassis Height 3U Width Standard 19 rack mount Power Supply Integrated Maximum Working Voltage HI to earth ground 230V max LO to earth ground 230V max Main Voltage Rating 115 230 V 50 60 Hz 40 VA AC Installation Category CAT II Environmental Operating Temperature 0 to 40 C Storage Temperature 5 to 40 C Humidity 80 for temperatures up to 31 C decreasing linearly to 50 RH at 40 C Maxi...

Reviews: