background image

Warranty & Support

This product is provided with a one year warranty for problems found during 

normal usage. Mistreating the Easi-Pulse or opening the unit will invalidate 

this warranty. Any data stored on the unit and any consequential loss is not 

covered by this warranty. The battery is not user replaceable.

Technical Support

Please visit www.tts-group.co.uk for the latest product information.

Email [email protected] for technical support.

TTS Group Ltd.

Park Lane Business Park

Kirkby-in-Ashfield

Nottinghamshire, 

NG17 9GU, UK.

Freephone: 0800 318686  Freefax: 0800 137525

TTS Product Code: 

EL00145

WARNING: Do not dispose of this product in 

household waste. Hand it over to a collection 

point for recycling electronic appliances. 

WARNING! Not suitable for children under 36 

months due to small parts – choking hazard. 

Made in China, on behalf of the TTS Group Ltd.

Easi-Pulse

TM

Nxxxxx

N448

Summary of Contents for Easi-Pulse

Page 1: ...tts group co uk for the latest product information Email feedback tts group co uk for technical support TTS Group Ltd Park Lane Business Park Kirkby in Ashfield Nottinghamshire NG17 9GU UK Freephone...

Page 2: ...measures the pulse oxygen saturation and pulse rate Easi PulseTM www tts shopping com USER GUIDE...

Page 3: ...e user and equipment Refer to the respective chapters for details Please read the User Manual carefully before using this product The User Manual which describes the operating procedures should be fol...

Page 4: ...r than 2 hours n The device cannot be clipped on the edema or tender tissue n Do not attempt to look directly at the infra red light emitter n Remove all cosmetics from the finger nail before use n Pl...

Page 5: ...ormance 4 2 Main Parameters 5 Installation 5 1 View of the front panel 5 2 Battery installation 5 3 Accessories 6 Operating Guide 6 1 Application method 6 2 Operation 6 3 Clinical restrictions 7 Maint...

Page 6: ...calibrated before leaving factory 1 2 Warning n Explosive hazard DO NOT use the oximeter in an environment with inflammable gas such as some ignitable anesthetic agents n Ensure that the environment i...

Page 7: ...value n If some abnormal symbols appear on the screen during use pull out the finger and reinsert to restore normal use n This device has an alarm users can check on this function according to chapte...

Page 8: ...hPa 1060hPa 3 Principle Principle of the Oximeter is as follows using Lambert Beer Law and according to Spectrum Absorption Characteristics of Reductive Hemoglobin Hb and Oxyhemoglobin HbO2 in glow ne...

Page 9: ...n be changed G A pulse rate sound indication H Alarm function I With SpO2 value and pulse rate data storage the stored data can be uploaded to computers J Data can be transmitted to computers 4 2 Main...

Page 10: ...esistance to surrounding light The deviation between the value measured in the condition of man made light or indoor natural light and that of darkroom is less than 1 F Power supply requirement 2 6 V...

Page 11: ...igure 4 Put finger in position Figure 3 A a Insert the two batteries ensuring the correct polarity and then replace the cover b Open the clip as shown in Figure 4 c Insert the finger into the foam rub...

Page 12: ...er two icons will appear on the desktop after installation SpO2 is a program for receiving real time data which is shown as Figure 5 the icon of SpO2 Review is a program for receiving stored data whic...

Page 13: ...u interface click the power button to select Alarm Press the power button 1sec to enter the alarm setting interface as shown in Figure 8 Press and hold the power button 1 second to enter the Settings...

Page 14: ...ick the power button to select high limit High or low limit Low Press the power button and hold to adjust the selected limit to the desired higher value and release the power button once the higher li...

Page 15: ...store the data or not choose on to allow storing choose off to prevent storing b If the data storage is turned on the main user interface will show a flashing yellow dot c Whilst recording the screen...

Page 16: ...adhesive E Excessive ambient light may affect the measuring result F Strenuous action of the subject or extreme electrosurgical interference may also affect the accuracy G Please clean and disinfect t...

Page 17: ...ot placed inside deep enough 2 The finger is shaking or the patient is moving 1 The battery is flat 2 The battery is installed incorrectly 3 The device is faulty 1 This device is set to automatically...

Page 18: ...button function button Type BF Serial number 1 the finger clip falls off no finger inserted 2 Probe error 3 Signal inadequacy indicator battery positive battery negative USB Ingress of liquids rank W...

Page 19: ...resolution is 1 70 100 2 Below 70 unspecified Calculate the Average value in every 4 measure value The deviation between average value and true value does not exceed 1 30bpm 250bpm the resolution is 1...

Page 20: ...f the user of the CMS50D should assure that it is used in such and environment Emission test RF emissions CISPR 11 RF emission CISPR 11 Compliance Group 1 Class B Electromagnetic environment guidance...

Page 21: ...he relative humidity should be at least 30 Mains power quality should be that of a typical commercial or hospital environment Guidance and manufacturer s declaration electromagnetic immunity for all E...

Page 22: ...ion applicable to the frequency of the transmitter Recommended separation distance Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer an...

Page 23: ...adcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If th...

Page 24: ...0 MHz to 800 MHz 800 MHz to 2 5 GHz 0 01 0 1 1 10 100 Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 0 23 0 74 2 33 7 38 23 33 For transmitters...