background image

T3-1

series

Ultrasonic Water Meter

Installation Instruction

Welcome use the T3-1 series ultrasonic water meter

The water meter be adapted by the advanced ultrasonic transit-time measurement technology

according to GB/T778.1-2007, IOS4064-1:2005 standard

1. Parts Description

Front View

Display:

Alarm/Error

Leak Detector

Wireless Power Supply

Communication

Permanent Fault

Battery Low Warning

Liquid Direction

Current Loop Connection

Pulse Output

Stable Flow Device

Standard:

1 485+

A

2 485 -

B

3 DC8-36V

4 GND

Provide below communication interface and output

1. RS485
2. M-BUS
3. DC8-36V
4.

Two-wired system 4-20mA output

5. OCT1

(open collector output 1)

6. OCT2

open collector output

2

7. C1

(TTL level pulse output 1

8. C2

(TTL level pulse output 2

Touch Key

Infrared Communication Interface

Ground Terminal

Batch Number

Label

Pipe Diameter and

Fluid Arrow Direction

Junction

Box Cover

Junction

Terminal

External Waterproof Junction Box

Can

complete

the

wiring

junction

without opening the water meter cover

PS:

when ordering, you can choose any two of the above communication

interface or output, lead to the external junction box

Back View

Summary of Contents for T3-1 Series

Page 1: ...ce Standard 1 485 A 2 485 B 3 DC8 36V 4 GND Provide below communication interface and output 1 RS485 2 M BUS 3 DC8 36V 4 Two wired system 4 20mA output 5 OCT1 open collector output 1 6 OCT2 open collector output2 7 C1 TTL level pulse output 1 8 C2 TTL level pulse output 2 Touch Key Infrared Communication Interface Ground Terminal Batch Number Label Pipe Diameter and Fluid Arrow Direction Junction ...

Page 2: ...ight pipe 3D At the highest point in the pipe system Vertical downward or slanted downward pipe Upstream straight pipe 3D ps Arrow direction is fluid flow direction 2 2 Installation Method 1 Confirm installation dimension 2 Cup off Water meter length L 2pcs sealing gasket thickness 10mm 3 Install matching flanges 4 Flanges position 5 Flanges welding 6 After cooling install with sealing gasket fast...

Page 3: ...l letter C Constant current method is no need the static flow When flow stable press calibration accumulator begin to count lowercase letter c will be flashing when require to stop press again In the calibration window second line on the display is average instantaneous flow rate of the calibration period time rather than the instantaneous flow rate instantly Its formular is average instantaneous ...

Page 4: ...er meter include 5 kinds of menus main menu secondary menu1 secondary menu2 batch control menu and time accumulated menu Under the main menu you can enter into any menu by the modification key Example M00 press enter into the month cumulative flow M03 press enter into secondary menu1 M10 M19 Under the M19 of the secondary men1 press enter into secondary menu2 M20 M2A M04 press enter into date cumu...

Reviews: