background image

 

 

Copyright

 

TSI Incorporated / 2007-2016 / All rights reserved. 

Address 

TSI Incorporated / 500 Cardigan Road / Shoreview, MN  55126 / USA 

Fax No. 

(651) 490-3824 

Limitation Of Warranty And Liability

 (effective February 2016) 

 

Seller warrants the goods, excluding software, sold hereunder, under normal use and 
service as described in the operator's manual, to be free from defects in workmanship 
and material for 

24 months

, or if less, the length of time specified in the operator's 

manual, from the date of shipment to the customer. This warranty period is inclusive of 
any statutory warranty. This limited warranty is subject to the following exclusions and 
exceptions:   

a. Hot-wire  or  hot-film  sensors  used  with  research  anemometers,  and  certain  other 

components when indicated in specifications, are warranted for 90 days from the date of 
shipment;  

b. 

Pumps are warranted for hours of operation as set forth in product or operator’s manuals; 

c.  Parts  repaired  or  replaced  as  a  result  of  repair  services  are  warranted  to  be  free  from 

defects  in  workmanship  and  material,  under  normal  use,  for  90  days  from  the  date  of 
shipment;  

d. Seller does not provide any warranty on finished goods manufactured by others or on any 

fuses, batteries or other consumable materials. Only the original manufacturer's warranty 
applies; 

e. This warranty does not cover calibration requirements, and seller warrants only that 

the instrument or product is properly calibrated at the time of its manufacture. 
Instruments returned for calibration are not covered by this warranty;   

f.  This warranty is 

VOID

 if the instrument is opened by anyone other than a factory 

authorized service center with the one exception where requirements set forth in the 
manual allow an operator to replace consumables or perform recommended cleaning;   

g. This warranty is 

VOID

 if the product has been misused, neglected, subjected to 

accidental or intentional damage, or is not properly installed, maintained, or cleaned 
according to the requirements of the manual.Unless specifically authorized in a separate 
writing by Seller, Seller makes no warranty with respect to, and shall have no liability in 
connection with, goods which are incorporated into other products or equipment, or which 
are modified by any person other than Seller.  

The foregoing is 

IN LIEU OF

 all other warranties and is subject to the 

LIMITATIONS

 

stated herein. 

NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR 

PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE. WITH RESPECT TO 
SELLER’S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT, SAID 
WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND EXCLUDES 
CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS. BUYER’S 
EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE PRICE 
DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT 

SELLER’S OPTION 

REPLACEMENT OF THE GOODS WITH NON-INFRINGING GOODS.

  

TO THE EXTENT PERMITTED BY LAW, THE EXCLUSIVE REMEDY OF THE USER 
OR BUYER, AND THE LIMIT OF SELLER'S LIABILITY FOR ANY AND ALL LOSSES, 
INJURIES, OR DAMAGES CONCERNING THE GOODS (INCLUDING CLAIMS BASED 
ON CONTRACT, NEGLIGENCE, TORT, STRICT LIABILITY OR OTHERWISE) SHALL 
BE THE RETURN OF GOODS TO SELLER AND THE REFUND OF THE PURCHASE 
PRICE, OR, AT THE OPTION OF SELLER, THE REPAIR OR REPLACEMENT OF THE 
GOODS. IN THE CASE OF SOFTWARE, SELLER WILL REPAIR OR REPLACE 

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30

Summary of Contents for AIRFLOW Model PVM620

Page 1: ...MICROMANOMETER ALNOR MODEL AXD620 AIRFLOW INSTRUMENTS MODEL PVM620 OPERATION AND SERVICE MANUAL P N 1980588 REV E FEBRUARY 2016 www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 2: ...d by anyone other than a factory authorized service center with the one exception where requirements set forth in the manual allow an operator to replace consumables or perform recommended cleaning g...

Page 3: ...of loss Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY AND LIABILITY which contains the complete and exclusive limited warranty of Seller This LIMITATION OF WARRANTY AND...

Page 4: ...CHAPTER 3 OPERATION 5 Keypad Functions 5 Common Terms 5 Menus 6 DISPLAY SETUP 6 PRESSURE ZERO 6 SETTINGS 6 FLOW SET UP 7 ACTUAL STANDARD SETUP 7 DATA LOGGING 7 Measurements 7 Log Mode Log Settings 8 D...

Page 5: ...ontainer Check the individual parts against the list of components below If anything is missing or damaged notify TSI immediately 1 Carrying case 2 Instrument 3 Pressure tubing 4 Static pressure tip 5...

Page 6: ...of the danger of battery acid leakage Using the Optional AC Adapter When using the AC adapter the batteries if installed will be bypassed Be sure to provide the correct voltage and frequency which is...

Page 7: ...setting a parameter Press the Menu soft key to select the Menu selections which are Display Setup Pressure Zero Settings Flow Setup Actual Std Set up Data Logging and Calibration Common Terms In this...

Page 8: ...is where you will setup the desired parameters to be displayed on the running screen With a parameter highlighted you can then use the ON soft key to have it show up on the running screen or select t...

Page 9: ...g the or key while on the main measurement screen Make adjustments with the or arrow keys and press to accept or enter the Select Kfactor menu to choose a different pre programmed flow value ACTUAL ST...

Page 10: ...Data Use this to delete all data delete test or delete sample Memory This option displays the memory available Delete All under Delete Data will clear memory and reset the memory available LogDat2TM...

Page 11: ...sing the CALIBRATION menu These field adjustments are intended to make minor changes in calibration to match a user s calibration standards The field adjustment is NOT intended as a complete calibrati...

Page 12: ...10 Chapter 4 Storage Remove the batteries when storing the unit for more than one month to prevent damage due to battery leakage www calcert com sales calcert com 1 800 544 2843 0 5 10 15 20 25 30...

Page 13: ...ow or dead batteries Replace batteries or plug in AC adapter Dirty battery contacts Clean the battery contacts Reading fluctuates unstable Fluctuating flow Reposition probe in less turbulent flow or u...

Page 14: ...low Rate Range Actual range is a function of actual velocity pressure duct size and K factor Instrument Temperature Range Operating 40 to 113 F 5 to 45 C Storage 4 to 140 F 20 to 60 C Instrument Opera...

Page 15: ...psi 190 in H2O 360 mmHg 48 kPa 2 Pressure velocity measurements are not recommended below 1 000 ft min 5 m s and are best suited to velocities over 2000 ft min Range can vary depending on barometric...

Reviews: