TN-M series crane scale technical manual
- 8 -
5.6 Sleep Mode
Press
SLEEP
key to enter sleep mode in normal weighing mode, the display only
show sleep indicator when in sleep mode;
Press
SLEEP
key again ,display will be back to normal weighing mode.
5.7 Auto Power Off Setting
It can set auto power off the crane scale, when scale not in use, scale will turn off
after the setting time. If want to enable the function,please see parameter
F9 OF
Press
TARE
key to select the options;
Press
ZERO
key to confirm;
Press
G/N
key to escape from the settings.
5.8 Back Light Setting
It can set back light when scale in use.
Hold
ZERO
key ,the display will be show
bk au;
Press
TARE
key to select the options;
Press
ZERO
key to confirm;
Note:If the battery gets low,the backlight function will not be available
5.9 Remote Controller
TN series crane scale can order remote controlled, you can find 4 keys at the
remote controller. the function is same with the crane scale except ON/OFF key.
Please pull out the antenna before operate the remote controller.The remote
controller operate distance is around 20m, but it
’
s depends on the operate environment.
The red LED must light up when any button is pressed. If it does not light up, the
batteries in the remote control must be exchanged.
F9 OF
Of 0
To set auto off function turn off, for scale always on
Of 5
Set to turn off 5 minutes later
Of 10 Set to turn off 10 minutes later
Of 20 Set to turn off 20 minutes later
Of 30 Set to turn off 30 minutes later
Bk au
To set auto option. When start to use back light will be on
and when stop the operation back light also will off.
Bk on
To set always on. After turn on the power, back light also
will be on.
Bk of
To set back light turn off. No back light in the operations