background image

TRP-C08D 

 

  USB to 1 RS232 and 1 RS422/485 Industrial Converter 

   

 

 
 
 
 
 
 
 

User’s Manual 

 
Printed Oct .24 2022 Rev 1.0   

Trycom Technology Co.,Ltd 

No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. 

Tel : 886-3-350-3351 Fax: 886-3-350-3352 

Web: www.trycom.com.tw 

 

 

Copyright 

Copyright Notice: The information in this manual is subject to change without notice to improve reliability, design and 
function and does not represent a commitment on the part manufacturer. No part of this manual may be reproduced, 
copied,  or  transmitted  in  any  form,  without  prior  written  permission  by  the  manufacturer.  Products  mentioned  in  this 
manual are mentioned  for  identification purposes only.  In this  manual,  product  names  appearing may  or may  not  be 
registered trademarks of their respective companies or copyright.   

Summary of Contents for TRP-C08D

Page 1: ...ion in this manual is subject to change without notice to improve reliability design and function and does not represent a commitment on the part manufacturer No part of this manual may be reproduced...

Page 2: ...a line Power and TXA RXA communication LED indicator Din Rail or panel mount Driver support Driver Support Android Windows 2000 WIN 7 WIN10 WIN11 and Linux 4 1 and Embedded Linux 5 5 1 2 Specification...

Page 3: ...2 Hardware Description 2 1 Panel layout 2 2 LED Indictor PWR LED System is ready RXA LED COMA RS422 485 Receiving TXA LED COMA RS422 485 Transmitting...

Page 4: ...s A null modem cable is required to make a connection between the PC COM port and the TRP C08D serial port 2 5 USB Connection The TRP C08D has a USB B Type connector which is fully compliant with USB...

Page 5: ...ndshaking Flow Control must be set to RTS CTS during configuration Refer to the Pin out table for connections 2 9 USB Cable Wiring TRP C08D is true USB 2 0 specification it also supports USB V1 0 V1 1...

Page 6: ...cessfully TRP C08D device detection can be confirmed by checking at the Device manager Check for High Speed USB MultiSerial Compound Device under Universal Serial Bus controllers and you will find Hig...

Page 7: ...ilities may help user to demo and test TRP C08D fast and easily User may find the utilities in Trycom support CD or download from Trycom web www trycom com tw direct to perform TRPCOM exe from the dir...

Page 8: ...Run the TRPCOM EXE utility STEP2 Click the Setting to set the com port and baud rate then press OK Please note COM2 is an example of COM port number the real COM number is assigned by user PC STEP3 Cl...

Page 9: ...ce such as connecting TRP C28 send 01M instruction from the client side when the TRP C28 received command that will response 01TRPC28 indicates execution completed Step1 Run TRPCOM exe utility Step2 C...

Page 10: ...Step3 Send command 01M and press Send button Step4 TRP C28 response received...

Page 11: ...7 TRP C08D Application...