20V
7
Start Up
The battery is shipped NOT CHARGED. It is necessary to charge the battery approximately 1 hour 20 minutes before being able
to use it. The normal charge is 32 °F to 113 °F. When not in this level the charge automatically stops until reaching the right
temperature. The normal temperature for discharge / work is 32 °F to 167 °F. If 167 °F are exceeded, the electronic control stops
the tool energy until the temperature reaches the temperature optimum new level. When the battery is below the normal
tension while working the tool stops working. Give the tool 15 minutes rest. In warm weather or after a long period of work the
battery will get too hot to recharge. Allow the battery to cool down before trying to charge again.
To install the battery into the tool handle, align the battery unit with the rails
on the inside of the tool handle and slide it into the handle until the battery
unit is firmly inserted into the tool; check that it does not slip out by itself.
To remove the battery from the tool, press the release button (
C
) and pull
the battery firmly out of the tool handle.
C
Battery use
Installing and Removing the Battery
• To rotate forward release the trigger and press the direction button on the
side where marks point towards the chuck.
• To reverse the turn, press it on the other side.
• The hammer drill will get blocked if the button sits in the middle.
• The first time you turn on the hammer drill and after
reversing rotation you might hear a click. This in normal and does not
represent a problem.
• To prevent damaging the tool, never reverse the
rotation direction while the hammer drill is running.
Direction of rotation
ENGLISH
CAUTION
CAUTION
Forward
Reverse
Nut or
Lug Inlet
Box Inlet
Impact
Die
Retaining
Ring
Die Set Up
Removing an accessory
• Set the direction button in the locked position (center).
• Take the die and push firmly onto the frame. The
retaining ring compresses to allow the accessory to slide
on top. Once the accessory is installed, the retaining ring
applies pressure which helps allow the accessory to be
retained.
WARNING
• To remove an accessory, grasp it and pull firmly.
• Always use impact dies with this tool. Do not use dies for
hand tools. Consult the catalog to
learn about our accessory’s variety.
• Use 1/2” dies for box.
• Using adaptors for other sizes are not recommended.
Use only if strictly necessary.
• If the die has orifices always use rubber rings and steel
tips when setting it into de box impeller.
• When the box is with a retaining ring, verify is in good
repair. If damaged, replace immediately.
• When a die has not been secured and
adjusted as indicated, it can shoot out and injure the
operator.
Summary of Contents for 101403
Page 10: ...20V 10 ENGLISH Notes...
Page 22: ...20V Notas 10 ESPA OL...