1. Check the lift gate for damage.
2. Manually open the lift gate in manual mode.
3. Check the control unit of the lift gate of the upper end posi-
tion. Correct display:
¯.Eo¯
.
4. Manually close the lift gate in manual mode.
5. Check the safety bar for proper function. The lift gate has to
open itself again.
6. Manually close the lift gate in manual mode.
7. Check the control unit of the lift gate of the lower end posi-
tion. Correct display:
_.Eu_
.
8. Place the system on automatic mode and lock the protection
doors.
The control unit must remain without any power; the system
is deactivated.
9. Carry out steps 1 to 8 on all lift gates.
Transport equipment (option): transport
belt
Maintenance interval: Every 6 months
Condition
■
Manual operating mode is active.
1. Manually move the transport belt, checking the belt for dam-
age while doing this.
2. Carry out checks on all transport belts.
BendMaster: Z axis
Maintenance interval: Every 6 months
1. Shut down the machine properly, secure the MAIN SWITCH
and secure with a padlock.
2. Check the toothed belt for damage and wear.
Position change of the Z axis by altered pitch.
Existing programs are no longer correctly processed.
Ø
Do not re-tension the toothed belt.
B579EN
2015-06-01
Mechanical elements
5
‐
11
106619:
Checking the conveyor belt
106621:
Checking the toothed belt
NOTICE
Summary of Contents for BendMaster 150
Page 1: ...Operator s manual BendMaster TruBend Cell 5000...
Page 2: ......
Page 3: ...Operator s manual BendMaster TruBend Cell 5000 Original operator s manual Edition 2015 06 01...
Page 6: ...II Before you proceed 2015 06 01 B579EN...
Page 16: ...0 10 Table of contents 2015 06 01 B579EN...
Page 44: ...1 28 Disassembly and disposal 2015 06 01 B579EN...