But-
tons
Operating
mode
How often should it be
pressed?
Consequences
Manual mode
or TruBend
manual
1. Press once.
■
The active catch is
deactivated.
■
The RED button
lights up.
What happens if…
Tab. 4-3
Note
If a person is still in the bending cell after starting the automatic
program:
■
Press the RED button on post 1 twice.
−
Press once: the system stops.
−
Press a second time: The catch is deactivated for 30 s.
−
Exit the bending cell.
−
To reset the deactivation of the 30-second catch:
Press the GREEN button in the mounting device of the
portable manual control unit for at least 3 seconds.
or
−
Press any EMERGENCY STOP button and press the
RED button on post 1 twice to deactivate the catch for
30 seconds.
1
GREEN button (post 1)
2
RED button (post 1)
Post 1
Fig. 41776
All EMERGENCY STOPs released
:
■
At TruBend (control system and control panel).
■
On the portable manual control unit.
4
‐
20
Operating the BendMaster
2015-06-01
B579EN
Function button on the
portable manual control unit
Enabling conditions for
manual press (TruBend
without BendMaster)
Summary of Contents for BendMaster 150