background image

6

Read the safety instructions and operating instructions 

carefully before starting the appliance. 

The vehicle owner 

is responsible for correct operation of the appliance.

The installer or vehicle owner must affix the yellow sticker 

with the warning information, which is enclosed with the ap-

pliance, in a location in the vehicle where it is clearly visible to 

all users. Missing stickers can be requested from Truma.

Function description

VarioHeat is a warm air heater for air circulation to heat camp-

ing vehicles quickly. The burner is fan-assisted, which ensures 

that operation is problem-free, even when on the move.

The appliance automatically selects the required operating 

level according to the temperature difference between the set-

ting on the control panel and the current room temperature.

A boost function for quick heating and a night function for 

low-noise operation are also available. The various fan set-

tings allow air circulation mode without heating.

The digital control panel can be used to select other functions 

such as time switch or operation of a Truma air conditioning 

system. Information on this can be found under Truma CP plus 

VarioHeat digital control panel

This appliance always starts up at the lowest setting. If this is 

not sufficient to achieve the desired temperature inside the 

vehicle, the appliance switches to a higher operating level af-

ter about 5 minutes.

Start-up

 

– Remove the cowl cover.

 

– Open the gas cylinder and the quick-acting valve in the gas 

supply line.

 

– Switch on the heater, see. 

Truma CP plus VarioHeat digital control panel

 or  

Truma CP classic VarioHeat analogue control panel

If the appliance is not used for a long period, place on the 

cowl cover and close the quick-acting valve in the gas supply 

line and the gas cylinder.

Room temperature sensor

To measure the room temperature, an external room tempera-

ture sensor is located in the vehicle. The position of the sensor 

is determined by the vehicle manufacturer depending on the 

vehicle model. More information can be found in the operat-

ing instructions for your vehicle.

Figure 1

The temperature setting on the control panel depends on per-

sonal heating requirements and the design of the vehicle, and 

must be determined individually.

Truma CP plus VarioHeat digital 

control panel 

Intended use

The Truma CP plus VarioHeat control panel is used to control 

and monitor a Truma VarioHeat heater and / or a Truma air 

conditioning system.

The following air conditioning systems can be operated with 

the Truma CP plus VarioHeat

1

:

 

– Saphir compact

2

 

– Saphir comfort RC

 

– Aventa eco

 

– Aventa comfort

Truma CP plus VarioHeat for the 

Truma air conditioning systems Aventa eco, Aventa comfort 

(from serial number 24084022 – 04/2013), Saphir comfort RC 

and Saphir compact (from serial number 23091001 – 04/2012)

The Truma CP plus VarioHeat is intended for installation in 

caravans and motor homes.

1

  And Truma CP plus VarioHeat CI BUS for CI BUS – not 

retrofittable.

2

  From serial number 23091001. In combination with a Truma 

VarioHeat heater, a “control panel cable coupling” is essential 

between the air conditioning system and the heater. Order the 

“control panel cable coupling” separately. Not in conjunction 

with inverter TG 1000 sinus.

Safety instructions

 

– Operate the Truma CP plus VarioHeat control panel only if it 

is in a technically perfect condition.

 

– Repairs must be carried out immediately. Only carry out 

repairs yourself if the solution is described in the trouble-

shooting guide of this operating instructions.

 

– Do not carry out any repair work or modifications on the 

Truma CP plus VarioHeat control panel.

 

– A defective Truma CP plus VarioHeat control panel may only 

be repaired by the manufacturer or the manufacturer’s ser-

vice department.

 

– Never use LP gas appliances when refuelling, in multi-storey 

car parks, in garages, or on ferries. Switch off the LP gas ap-

pliance on the Truma CP plus VarioHeat control panel.

Important notes

 

– If the power supply to the system has been interrupted, the 

time / time switch must be reset.

 

– If a new or replacement appliance (heater, air conditioning 

system) is connected to the bus system, the procedure de-

scribed in “Initial start-up” must be repeated.

Air conditioning systems – shared use of 

IR remote control and Truma CP plus VarioHeat 

control panel

 

– Even after connecting the Truma CP plus VarioHeat control 

panel, the IR remote control is available for controlling the 

air conditioning system. The Truma CP plus VarioHeat con-

trol panel recognises all settings that are made using the 

IR remote control on the air conditioning system. The IR 

remote control only transmits the settings that are shown in 

its display (no bidirectional communication).

 

– Only the time switch of the Truma CP plus VarioHeat control 

panel may be used to clearly define the start and end time 

of a required period.

Operating instructions 

Summary of Contents for VarioHeat

Page 1: ...Operating instructions Page 2 To be kept in the vehicle Truma VarioHeat...

Page 2: ...lid laws di rectives and standards must be observed Not following the rules in the operating and installation instructions can result in serious material damage and can seriously put at risk the healt...

Page 3: ...appliance must not be operated during refuelling the vehicle the caravan s towing vehicle or other appliances Switch off the LP gas appliance at the control panel Shut off the gas supply to the LP ga...

Page 4: ...vehicles with a fixed output pressure of 30 mbar may be used for the gas system The flow rate of the pressure regulating equipment must correspond to at least the maximum consumption of all appliance...

Page 5: ...s supply and switch off the appliance Danger of fire explosion if you attempt to use an appliance that has been dam aged by flooding or if the vehicle has been involved in an accident A damaged applia...

Page 6: ...plus VarioHeat control panel is used to control and monitor a Truma VarioHeat heater and or a Truma air conditioning system The following air conditioning systems can be operated with the Truma CP pl...

Page 7: ...nu item Service menu RESET PR SET After confirmation the Truma CP plus VarioHeat control panel initialises itself INIT appears on the display while this is in progress The appliances that have been fo...

Page 8: ...conditioning system is in heating mode e VENT Air conditioning system is in air circulation mode Quick temperature change possible using rotary push button in stand by screen Select fan level With con...

Page 9: ...rotary push button 24 h mode 12 h mode Figure 12 a m p m Figure 13 If the start end point was exceeded during entry the op erating parameters are not taken into consideration until the next start end...

Page 10: ...or of the heater OFFSET The room temperature sensor of the heater can be individu ally adjusted to the sensor s installation situation The set ting can be made in increments of 0 5 C within the range...

Page 11: ...ing parameter is within the target range again this symbol goes off again automatically Figure 30 Read out code of warning Select icon with rotary push button Tap the rotary push button The current wa...

Page 12: ...control knob When the appliance is on heating or ventilation the green LED must light up the fan is on If the LED does not light up check the main switch if necessary Please observe the respective ve...

Page 13: ...12 V Truma VarioHeat eco 0 65 2 75 A Truma VarioHeat comfort 0 65 2 75 5 4 A Quiescent current consumption with Truma CP plus VarioHeat 0 004 A with Truma CP classic VarioHeat 0 001 A Weight Heater w...

Page 14: ...ll also be applicable 2 Warranty exclusions No warranty claim shall be applicable under the following circumstances Improper unsuitable faulty or negligent use and any use that is not compliant with t...

Page 15: ...blocked End outlets EN closed up Remove blockage Remove blockage Open end outlets EN 28 Open window above cowl window switch Close windows 29 Risk of low voltage battery voltage too low 10 4 V Charge...

Page 16: ...osed Gas cylinder empty Gas pressure regulation system iced up Butane content in the gas cylinder too high Combustion air infeed or exhaust outlet is sealed Check gas supply and open valves Replacing...

Page 17: ...vice partners see www truma com In order to avoid delays please have the unit model and serial number ready see type plate Truma Ger tetechnik GmbH Co KG Wernher von Braun Stra e 12 85640 Putzbrunn De...