13

–  Combi 6 (E):

 

In order to prevent heat accumulation when using the 
Combi 6 (E), all 4 warm air connecting pieces must be 

attached. The cross-section of the hot air pipes must not be 
reduced by pipe connections or the like. If an EN end outlet 
that can be closed off is installed in one of the Combi 6 (E) 
warm air ducts (e.g. in the bathroom), a second outlet that 
cannot be closed off must be  installed in the warm air duct.

–  Combi 4 (E):

  With Combi 4 (E), all four or only three hot air outlets can be 

occupied (Truma always recommends four hot air outlets for 
optimal distribution of warm air!). If only three hot air outlets 
are needed, one of the lower hot air outlets must be sealed 
with a blank cover VD (part no. 34310-01). The blank cover 
must be firmly pushed into the moulded part of the heater 
until it audibly engages and is firmly seated. Please check 
that the cover is firmly seated.

 

If using four hot air outlets, a closable end outlet EN 
may be installed in 

one

 hot air branch. If just 3 warm 

air outlets are being used, it must be noted that a second 
nozzle that cannot be closed off must be installed in the 
warm air duct if an end piece that can be closed off is being 
used (e.g. in the bathroom).

The warm air system is designed for each type of vehicle indi-
vidually, on a modular basis. There is an extensive accessories 
program available. Diagrams showing optimum hot air system 
installation suggestions in all of the common caravan and mo-
tor home models can be requested free of charge from the 
Truma Service Centre.

Gas connection

The gas supply’s operating pressure (30 mbar) must 
be the same as the unit’s operating pressure (see type 

plate).

Choose to route the pipes in a way that will facilitate removing 
the unit for service tasks.

19

20

The gas supply line (8 mm dia.) must be attached to gas-con-
nection muff (20) with olive screw fitting (19 – included in 
delivery). Carefully counterhold with another spanner when 
tightening!

Gas-connection muff (20) on the unit may not be shortened 
or bent.

Prior to connecting the appliance make sure that the gas lines 
are free from dirt, chips and such!

Keep the number of parting connections in the gas supply 
line in rooms frequented by people to a technically feasible 
minimum. 

The gas system must comply with the technical and 
 administrative regulations of the respective country of use 
(e.g. EN 1949 in Europe).

The national legislation and regulations (e.g. DVGW Work 
Sheet G 607 for vehicles in Germany) must be observed.

Water connection

For operating the water heater it is possible to use all pressure 
pumps and submergible pumps up to 2.8 bar, also all mixing 
taps with or without electrical switch.

If using immersion pumps, a non return valve (21 – not in-
cluded in delivery) must be installed between the pump and 
the first branch. Observe the direction of flow when installing 
the non return valve.

21

26

24

23

29

28

25

27

When using pressure pumps with high switching hysteresis, 
hot water may flow back via the cold water tap. We recom-
mend installing a non return valve (22 – not included with 
delivery) between the outlet to the cold-water cock and 
 FrostControl as a return flow inhibitor. Observe the direction 
of flow when installing the non return valve. 

29

28

26

25

24

22

23

27

For attachment to the boiler and FrostControl, you must use 
drinking water compatible hoses that are pressure-resistant 
and hot water-resistant up to 80 °C with an inside diameter 
of 10 mm.

For routing rigid pipes (e.g. John Guest System) Truma can 
supply the elbow fittings (27 + 28), the FrostControl (24) and 
a non-return valve (21 + 22) with a 12 mm inner connection 
as accessories. In this case we recommend the use of John 
Guest pipes, insertion sleeves and hose clamps in all cases.

When connecting to a central water supply (rural or city 
mains) or if using more powerful pumps, a pressure reduc-
tion valve must always be installed which prevents pressures 
above 2.8 bar from developing in the water heater.

Route water ho ses as short as possible and free of kinks. 
All hose con nections must be secured with hose clamps 
(also cold water hoses)! Before the pressure relief valve in 
 FrostControl triggers, warming of the water and its resulting 
expansion may cause pressure of up to 3.8 bar to occur (also 
possible with immersion pumps).

Hose clips SC (part no. 40712-01) are suitable for fastening 
the hoses to walls or the floor. These hose clips also make it 
possible to route water hoses on the heater‘s warm-air distri-
bution pipes as a way to avoid the danger of frosting.

The included elbow fittings (27 + 28) must always be 
used in order to completely empty the water and prevent 

the water hoses on the unit from leaking over the long-term!

Elbow fitting (28 – with aeration valve) is connected to the 
 upper warm water connection; the second elbow fitting (27) is 
connected to the lower cold water connection.

Summary of Contents for Combi 4 E CP plus

Page 1: ...llation instructions Page 10 Istruzioni di montaggio Pagina 24 Inbouwhandleiding Pagina 31 Monteringsanvisning Side 38 Instructions de montage Page 17 Instrucciones de montaje P gina 45 Komfort f r un...

Page 2: ...i montaggio 1 Unit di comando 2 Sensore di rilevamento della temperatura ambiente 3 Aspirazione dell aria di ricircolo min 150 cm 4 Tubi dell aria calda 5 Uscite dell aria calda 6 Camino di scarico a...

Page 3: ...tfahrzeugen Motorcaravans Klasse M1 f r Personenbef rderung mit h chstens 8 Sitzpl tzen au er dem Fahrersitz sowie f r Anh nger Caravans Klasse O zugelassen Das Jahr der ersten Inbetriebnahme muss auf...

Page 4: ...oder mit einem Gef lle von max 20 cm verlegt werden Rohrl ngen ab 100 cm bis max 150 cm d rfen nur steigend verlegt werden 350 180 17 18 500 540 500 12 10 10 10 18a Mindestma e je nach Einbausituation...

Page 5: ...igen Anschluss Abgas Doppelrohr ans Ger t 6 3 2 3 Nm 4 1 5 7 Abgasrohr 1 am Anfang zusammenstauchen so dass Win dung an Windung liegt Schelle 4 Krallen zum Ger t ber das Abgasrohr 1 schieben Schelle 7...

Page 6: ...Der Betriebsdruck der Gasversorgung 30 mbar muss mit dem Betriebsdruck des Ger tes siehe Typenschild bereinstimmen Die Rohrverlegung so w hlen dass das Ger t f r Service arbeiten leicht ausgebaut wer...

Page 7: ...schlauch und Bohrung von unten mit plastischem Karosseriedichtmittel abdichten FrostControl mit 2 Schrauben B 5 5 x 25 im Lieferumfang enthalten befestigen Verlegung der Wasserleitungen Kaltwasserzula...

Page 8: ...er Bedienteilkabel 6 m Art Nr 34020 21400 Kupplung Art Nr 34020 21500 Verl ngerungskabel 3 m inkl Kupplung Art Nr 34301 02 Verl ngerungskabel 6 m inkl Kupplung Art Nr 34301 01 Zum optischen Abschluss...

Page 9: ...t 1 2 Vss betr gt F r die unterschiedlichen Anwendungsf lle empfehlen wir die Ladeautomaten von Truma Bitte fragen Sie Ihren H ndler Andere Ladeger te nur mit einer 12 V Batterie als Puffer verwenden...

Page 10: ...allation in passenger vehicles class M1 motor caravans with no more than 8 seats exclud ing the driver s seat and for trailers class O caravans The year when the equipment was first taken into oper at...

Page 11: ...inimum dimensions additional space must be provided for the gas connection water connections and the FrostControl depending on the installation situation All dimensions in mm In order to reduce the po...

Page 12: ...duct 1 all the way onto muff 3 Slide clamp 4 to the end the end position must be between the clamp s claws and screw in place Slide combustion air infeed 5 onto muff 6 and secure with clamp 7 Recircu...

Page 13: ...ctive country of use e g EN 1949 in Europe The national legislation and regulations e g DVGW Work Sheet G 607 for vehicles in Germany must be observed Water connection For operating the water heater i...

Page 14: ...onnection with integrated vent valve 28 to the hot water consumers Push the venting hose external diameter 11 mm 29 onto the hose grommet of the venting valve 32 and lay it to the outside without any...

Page 15: ...ec tion cover 39 The cover can be removed by pressing and simultaneously sliding it in the direction of the arrow When removing or installing the connection cover on the connec tion cables make sure t...

Page 16: ...mbi 4 E Combi 6 E The electrical connection is only to be carried out by an expert in accordance with VDE 0100 part 721 or prIEC 60364 7 721 in Germany The information given here is not intended as in...

Page 17: ...places assises maximum hors si ge conducteur ainsi que pour les remorques caravanes classe O L ann e de la premi re mise en marche doit tre coch e sur la plaque signal tique Instructions de montage Pr...

Page 18: ...lation de 20 cm max Les longueurs de tuyau entre 100 cm et 150 cm doivent tre pos es uniquement en pente montante 350 180 17 18 500 540 500 12 10 10 10 18a Dimensions minimum selon la situation de mon...

Page 19: ...e tuyau d vacuation 1 Pousser la bride 7 sur le tuyau d alimentation en air de combustion 5 Pousser le tuyau d vacuation 1 sur le manchon 3 jusqu la but e Pousser la bride 4 jusqu la but e La but e do...

Page 20: ...uret de copeaux et autres Dans les locaux fr quent s par des personnes limiter le nombre des raccordements de la conduite de gaz au stricte n cessaire du point de vue technique L installation de gaz d...

Page 21: ...ord d eau froide et le raccord coud vanne de ven tilation int gr e 28 sur le tuyau de raccord d eau chaude du chauffage Tirer en sens inverse pour v rifier le bon enfonce ment des raccords coud s tabl...

Page 22: ...m n d art 34020 21400 Accouplement n d art 34020 21500 Rallonge de c ble de 3 m accouplement inclus n d art 34301 02 Rallonge de c ble de 6 m accouplement inclus n d art 34301 01 Pour la finition du c...

Page 23: ...r les diff rentes conditions d utilisation nous recomman dons le chargeur automatique de Truma Veuillez demander votre concessionnaire Les autres chargeurs doivent tre utili s s uniquement avec une ba...

Page 24: ...te al consumo umano Questa stufa omologata per il solo montaggio in autoveicoli autocaravan classe M1 per il trasporto di persone con un massimo di 8 posti a sedere conducente escluso e in rimor chi c...

Page 25: ...piacere o con una pendenza max di 20 cm Posare i tubi di lunghezza compresa tra 100 cm e max 150 cm solo in direzione ascendente 350 180 17 18 500 540 500 12 10 10 10 18a Dimensioni minime a seconda...

Page 26: ...graffe rivolte verso l apparecchio sul tubo di scarico 1 Far scorrere la fascetta 7 sul tubo di alimentazione dell aria di combustione 5 Spingere il tubo di scarico 1 sul bocchet tone 3 fino all arre...

Page 27: ...sto dal punto di vista tecnico L impianto a gas deve essere conforme alle norme tecniche ed amministrative del rispettivo paese di utilizzo in Europa ad es EN 1949 Devono essere osservati i regolament...

Page 28: ...che i raccordi ad angolo siano inseriti saldamente in posizione provando a tirarli Realizzare il collegamento flessibile 25 per la mandata del l acqua fredda tra il FrostControl 24 e la mandata sul bo...

Page 29: ...ertura 37 Accessori per l unit di comando e il selettore dell alimentazione energetica Cavo per unit di comando di 6 m di lunghezza n art 34020 21400 Innesto n art 34020 21500 Prolunga di 3 m di lungh...

Page 30: ...caricabatteria di Truma Rivolgersi al proprio rivenditore Utilizzare altri caricabatteria solo con una batteria da 12 V come buffer Collegamento del sensore temperatura ambiente sulla stufa Inserire...

Page 31: ...er met maximaal 8 zitplaatsen buiten de chauffeursstoel alsmede voor aanhan gers caravans klasse O Het jaar van de eerste ingebruikname moet op de typeplaat worden aangekruist Inbouwhandleiding Voorsc...

Page 32: ...en maximale lengte van 100 cm naar wens stijgend of met een verval van max 20 cm worden aangebracht Buislengtes vanaf 100 cm tot max 150 cm mogen alleen oplopend worden aangelegd 350 180 17 18 500 540...

Page 33: ...bineerde aan afvoerbuis op het toestel aansluiten 6 3 2 3 Nm 4 1 5 7 Afvoerbuis 1 bij het begin samendrukken zodat de winding op de winding ligt Klem 4 klauwen naar het toestel toe over afvoerbuis 1 s...

Page 34: ...ma servicecentrum gratis worden aangevraagd Gasaansluiting De werkdruk van de gasvoorziening 30 mbar moet overeenstemmen met de werkdruk van het toestel zie typeplaat De buis zo aanleggen dat het toes...

Page 35: ...sen afvoerslang en boorgat van onder met kneedbaar carosseriekit afdichten Frostcontrol met 2 schroeven B 5 5 x 25 in de leve ring inbegrepen bevestigen Waterleidingen aanleggen Koudwatertoevoer 23 op...

Page 36: ...ppeling art nr 34020 21500 Verlengkabel 3 m incl koppeling art nr 34301 02 Verlengkabel 6 m incl koppeling art nr 34301 01 Voor optische afsluiting van de afdeklijst 37 levert Truma zij delen 38 in 8...

Page 37: ...stellen mogen enkel met een batterij van 12 V als buffer gebruikt worden Aansluiting binnentemperatuurvoeler op het toestel Stekker van de aansluitkabel op de aansluiting 46 steken er hoeft niet op po...

Page 38: ...6 95 EF Varmeovnen opfylder direktiv 2000 53 EF vedr gamle k ret jer og direktiv 98 83 E F vedr drikkevand Varmeapparatet er tilladt til montering i k ret jer autocam pere klasse M1 til personbefordri...

Page 39: ...0 l ngere end forbr ndingslufttilf ringsr ret 5 Herved undg s at aftr ksr ret uds ttes for str kning og tr kbelastning 350 180 17 18 500 540 500 12 10 10 10 18a Minimumsm l afh ngigt af monteringssitu...

Page 40: ...s r ret 5 p studsen 6 og fastg r det med sp ndeb ndet 7 Cirkulationsluftindtag Cirkulationsluften suges ind i anl gget Dette skal ske via en stor eller flere mindre huller med en samlet overflade p mi...

Page 41: ...op til 2 8 bar anvendes og det samme g lder alle blandingsbatterier med eller uden elkontakt Ved anvendelse af dykpumper skal der monteres en kontra ventil 21 ikke indeholdt i leveringen mellem pumpen...

Page 42: ...ilationsventilens 32 slangetylle og tr kkes udvendigt uden kn k Buens radius m ikke v re mindre end 40 mm Sk r udluftningsslangen af cirka ca 20 mm under k ret jets bund og med et 45 skr t snit i forh...

Page 43: ...47 Betjeningsedel Diagnosestik 48 Betjeningsedel Diagnosestik Alternative tilslutninger for en betjeningsdel Combi 4 Combi 6 eller en energi valgknap Combi 4 E Combi 6 E og et diagnosestik Al tilslutn...

Page 44: ...d som De har bedt om at udf re arbejdet Det er vigtigt at der s rges for omhyggelig tilslutning i de rigtige farver I forbindelse med service og reparationsarbejde skal der fore findes en anordning ti...

Page 45: ...ajeros con un m ximo de 8 plazas adem s del asiento del conductor as como para remolques caravanas clase O El a o de la primera puesta en marcha debe marcarse con una cruz en la placa identificadora N...

Page 46: ...eza de conexi n ni ninguna abertura de ventilaci n del tanque Adem s a una distancia de 300 mm a la chimenea no debe haber ninguna abertura de ventilaci n para el rea de vivienda o ventanas que se abr...

Page 47: ...adera 7 desde dentro en la tubuladura 12 y en caso de longitudes superiores a los 60 cm fijarlo con al menos una abrazadera ZRS 16 N de art 39590 00 a la pared Conexi n del tubo doble de los gases de...

Page 48: ...gas de 30 mbar debe coincidir con la presi n de servicio del aparato v ase la placa de caracter sticas Seleccionar el tendido de tuber a adecuado para que el apara to pueda desmontarse f cilmente a l...

Page 49: ...o flexible de vaciado y el orificio desde abajo con impermeabilizante pl stico de carrocer as Fijar el FrostControl con 2 tornillos B 5 5 x 25 incluidos en el volumen de suministro Tendido de las tube...

Page 50: ...d de mando de 6 m N de art 34020 21400 Elemento de conexi n N de art 34020 21500 Cable de prolongaci n de 3 m que incluye elemento de conexi n N de art 34301 02 Cable de prolongaci n de 6 m que incluy...

Page 51: ...ue la ondulaci n de tensi n alterna sea 1 2 Vss Para aplicaciones diferentes recomendamos usar el cargador autom tico de Truma Por favor consulte a su proveedor Los otros cargadores deben utilizarse e...

Page 52: ...a e de montagem podem ser solicitadas junto ao fabricante Truma ou da assist ncia t cnica da Truma no seu pa s N vod k pou it a mont n n vod si lze v e i Va zem vy dat u v robce Truma nebo servisu Tr...

Reviews: