Truly TET-340 User Manual Download Page 1

This thermometer has a memory for 

10 readings. After each reading, the 

temperature is automatically 

recorded in the first empty memory.

If all the memory space is used, the 

first memory is automatically 

deleted and replaced by the new 

reading and so on. 

To read the memorised 

temperatures: The product must be 

switched off.

• Press the button       until 

   MEMORY appears on the screen. 

   The information appears on the

   screen alternately.

   example :

• To read all of the 10 temperature 

   readings in the memory, press 

   briefly and successively on       : 

   the different temperatures are 

   displayed one after another as 

   the ear or forehead mode in

   which they have been taken.

• To exit the memory mode, press 

   the button       or wait for the 

   thermometer to switch off

   automatically.

To delete the memorised 

temperatures:

• Enter in memory mode .

• Press       until           appears.

   The thermometer switches off  

Switching off

To switch the appliance off:

Press the button       until the 

screen displays OFF. Or the 

appliance switches off automatically 

after 60 seconds.

Memory function

Infrared Ear & Forehead Thermometer

MODEL: TET-340

User Manual

Rev.00    2011/06/14

MANUFACTURER: Truly Instrument Ltd.

                                   2/F., 

                                   Chung Shun Knitting Centre,

                                   1-3 Wing Yip St, Kwai Chung, 

                                    N.T., HONG KONG

TEL: (852) 2487 9803

FAX: (852) 2146 5756, 2480 0018, 2480 0126

EC-REPRESENTATIVE: 

Wellkang Ltd t/a 

Wellkang Tech Consulting Suite B,

29 Harley Street, 

LONDON W1G 9QR, 

United Kingdom

-1-

-2-

-3-

-4-

-8-

-7-

-6-

-5-

1. Lens

2. Probe

3. Battery compartment

4. Luminous diodes to show 

    temperature mode : ear or 

    forehead

5. Screen

6. Take temperature and 

    memory function button

7. On/Off and Ear or forehead 

    temperature Mode button

8. Protection/vertical storage cap.   

Description

Precautions for use

This ear and forehead 

thermometer receives the infra-red 

rays emitted by the skin’s surface 

and in the ear drum area. It allows 

you to check your child’s 

temperature easily. This is how to 

use the appliance:

• TET-340 is exclusively dedicated 

   to take ear or forehead 

   temperatures. We would like to 

   re-iterate that this appliance does 

   not replace the advice of a doctor. 

   In case of doubt or fever, contact 

   your doctor. 

   The simple take of temperature 

   cannot be considered as a 

   medical advice, DO NOT modify 

   the proportion of any drugs 

   prescribed by your doctor without 

   seeking medical advice first.

• To ensure the reading is accurate, 

   the probe and the lens must be 

   absolutely clean.

• Do not use the thermometer if it 

   has been dropped or shows any

   signs of damage.

• Always place the protection cap 

   back after use.

• In cases of movement from one 

    

Warning, this appliance is 

not suitable for detecting  

hypothermia.

Average temperatures

   room to another, wait for half an 

   hour minimum before using the 

   appliance.

• Wait for half an hour after 

   physical training, bathing or 

   eating before measuring 

   temperature.

• Keep the thermometer out of 

   reach of children.

• Do not expose the thermometer:

   - To any warm sources (radiator, 

     sun rays, ...)

   - To dust or humidity.

• Never immerse the thermometer 

   in liquid.

• Do not touch the lens with your 

   fingers.

BODY TEMPERATURE: the normal 

human body temperature varies 

during the day. It is measured

along a scale of values defined 

according to the part of the body 

where the temperature is taken:

   - Rectal measurement: 

     36,6°- 37,8°C

   - Axillary measurement 

     (under the arm): 34,7°- 37,3°C

   - Oral measurement (in the 

     mouth) or forehead: 

     35,5°- 37,5°C

   - Ear measurement: 

     35,8°- 37,8°C

Forehead temperature
Ear temperature
Rectal temperature
Oral temperature
Axillary temperature

36.1°C
36.4°C

37.0°C
36.6°C
36.1°C

Technical specifications

Comments: these technical 

specifications may be subject to 

modifications to improve the 

appliance, without prior warning.

Installing the battery

The appliance is delivered with a 

lithium battery 3V (CR2032) 

already in place. At the first use, 

open the battery cover then 

remove the strip which ensures the 

protection of the battery (fig. 1/

fig. 2). Replace the cover (fig. 3).

Installing the battery, Open the 

battery compartment and place a 

new button lithium battery CR2032 

3 volts po on the top. 

Replace the cover. 

Keep the battery out of reach of 

children.

IMPORTANT: When installing a new

battery. always wait half hour an 

hour before using the appliance.

Screen resolution

0.1°C

Measurement 
range 

20°C - 42.2°C

Precision

32°C ~ 42°C: 
+/-0.2°C
<32°C and >42°C
+/-0.3°C

Operation 
conditions-room 
temperature

+16°C / + 35°C 
Relative humidity 
less than 85%

Storage conditions -20°C / +80°C 

Relative humidity 
less than 95%

Energy source 

1 lithium battery 
3V type CR2032 
Service life: 
approximately 
5000 measures

As for all thermometers, slight 

variations in temperature may be 

displayed one after another:

it is therefore recommended to 

take several readings (removing the 

thermometer from the ear between 

each reading) and take the highest 

reading into account.

Forehead measurement

• Remove the protection cap.

• To switch on press and maintain 

   the button        until the 

   indications in fig. 4 are displayed

   in the screen the appliance comes 

   automatically displays the Ear 

   mode.

• Press the button       to select the 

   forehead mode. The screen 

   shows the corresponding 

   function fig. 7 and the luminous 

   diode corresponding to the 

   symbol        blink 5 times.

• Place the probe in the middle of 

   the forehead. Press the button

         . Slowly slide the probe on

   the skin to the temple fig. 8. 

• While taking the temperature, the 

   screen indicates          and audible 

   bips sound.

• As soon as the probe is placed on 

   the area of the temple, release 

   the button       , wait for the

   validation sound beep before 

   removing the thermometer.

• Read the temperature on the 

   screen.

• The temperature is automatically 

   recorded.

Notice:

This temperature reading must be 

considered as an estimation.

The temperature reading of the 

forehead can be influence by 

environmental conditions

because the probe is more sensitive 

to perspiration, sebum, physical 

activity and environmental 

temperature.

It is recommended that you wipe 

the forehead before taking a

reading. In case of important

differences or if in any doubt, the

ear measurement must be pointed

Ear measurement

• Remove the protection cap.

• To switch on press and hold the 

   button        until the indications 

   in fig. 4 are displayed in the 

   screen the appliance automatically 

   displays the Ear mode. The screen 

   shows the corresponding function 

   fig. 5 and the luminous diode 

   corresponding to the symbol          

   blink 5 times.

• Gently pull the ear upwards and 

   backwards to straighten the ear 

   canal. Insert the thermometer into 

   the ear canal fig. 6.

• While continuing to hold the ear, 

   press       . During the taking of 

   temperature, the screen indicates  

            .

• Wait for the validation sound 

   beep before releasing the button 

   and removing the thermometer.

• Read the temperature on the 

   screen.

• The temperature is automatically 

  recorded.

Specific messages

Specific messages

Notice:

• For optimal precision, the ear 

   should not be obstructed by wax 

   or a plug.

• Do not use this thermometer with 

   an ear infection (otitis). Moreover, 

   if your child has had several ear 

   infections, the measurement will 

   be less accurate. 

out. We remind you that there is a 

significant difference between an 

ear temperature reading and a 

forehead temperature reading. 

automatically.  

The ear and forehead thermometer 

has been designed to give precise 

information. 

If the following messages appear 

on the screen, refer to the table 

below and follow the instructions : 

Battery energy 

is low.
The battery is 

dead.

The temperature 

reading exceeds 

the range of 

possible 

temperatures.

The temperature 

reading is below 

the range of 

possible 

temperatures.

The temperature 

reading is out 

the range of 

possible 

temperatures.

Change the 

battery. If the 

screen remains

white, contact a 

TRULY after 

sales service

center.

Change the 

battery.

Take the 

temperature 

reading again.

Take the 

temperature 

reading again.

Place the 

thermometer in 

a room where

the temperature 

is between 

16°C and 35°C 

and wait at 

least 30 minutes 

before taking 

the temperature 

again.

8

1
2

3

4

5

6

7

fig. 2

fig. 1

fig. 8

fig. 3

fig. 6

fig. 5

fig. 4

fig. 7

clean the body of the thermometer 

using a soft cloth; The probe can be 

cleaned with cotton soaked in 

disinfectant; The lens can be 

cleaned with cotton gently soaked 

in disinfectant.

Reviews: