truflo TKB Series Installation Manual Download Page 1

TKB SERIES BATTERY OPERATED FLOW METER

The TKB Series Paddle Wheel Flow Meter has been Factory 

Programmed         

No K-Factor Programming Required

To Ensure

 

Full Pipe

 

     Please Follow the 

 Installation

 Instructions on

  (pg 5)

 

TK

B

 SERIES

INSTALLATION MANUAL 

Important 

!

Summary of Contents for TKB Series

Page 1: ...ED FLOW METER The TKB Series Paddle Wheel Flow Meter has been Factory Programmed No K Factor Programming Required To Ensure Full Pipe Please Follow the Installation Instructions on pg 5 TKB SERIES INSTALLATION MANUAL Important ...

Page 2: ...re Non Shock 10 1 Real Time Paddle Tefzel Bodies PVC PP PVDF SUS 316 Rotor Bearings Zirconium Ceramic Operating Temperature PVC 60 C PP 80 C PVDF 110 C ST 120 C Ambient Temperature 20 C 80 35 85 RH 5 RoHS Compliant Protection Class NEMA 4X IP 66 Approval CE Rohs 5 01 1 Energy Saving ECO Mode Option 2 Units of Measurement 2 1 Flow Rate GPM LPM TPM Range 0 0 999 9 2 2 Totalizer GAL LTR KL Range 0 99...

Page 3: ...grammable Unit Gallon Liter KL Range 0 0 999 9 Programmable Units GPM LPM TPM 3 0 VDC Lithium Battery CR2477T 2 Years Under Normal Operating Conditions Polycarbonate UL 94V0 49 0 68 2 67 0 70 2 65 0 360 1 2 3 4 8 1 2 3 4 5 6 7 Polycarbonate Cover Flow Controller Hall Effect Sensor Paddle Wheel Tefzel Zirconium Ceramic Rotor Pin Bearings Removable Battery Cover Battery 5 02 6 7 8 Body Material PVC ...

Page 4: ...360 Press Remove Cover Battery Replacement Procedure to Rotate Display 1 2 3 4 03 ...

Page 5: ...abled dt 10 Flow Alarm Delay Press key Status Display SET SET 04 Factory Unlock Number is 8 Enter ANY Number from 0 9 to Set Password Press Key for 5 sec SET F F Press key Press key or Display Flashing Press to Select Display Flashing Press to Select or Display Flashing Press to Select or or Display Flashing Press to Select Press to Select or Programming Alarm Delay time sec Programming Backlight ...

Page 6: ...s 3 2 After releasing the key the current value of the 1st 6th digits will be displayed ECO GAL K L GPM LPM TPM LTR Flow Rate Flow Total Battery Life Mode of Operation Eco Extended Battery Life 05 Press and Hold Set for 3 Sec to Change from Flow Rate to Flow Total Press Hold for 3 Seconds to view 8 9 digits while in Totalizer Screen 6 Displaying Flow Rate Flow Totalizer Totalizer Reset r indicates...

Page 7: ...3x Pipe Diameters Downstream TKR Series can be installed in a Horizontal or Vertical direction A Plastic Basket Strainer Bag Filter or Y Strainer Filtering Device upstream to Avoid the Paddle Wheel from being damaged by the solids or fibers max 10 Particle Size Not to Exceed 5mm Cross Section or Length Installation Positions 06 For More Information Please Contact Us 905 469 9283 sales iconprocon c...