Product specifications 

Product Code:

 PR10000X 

AirSim Pierre Robin X weight:

 Approx. 2kg 

Shipment dimensions:

 32 x 19 x 19cm 

 

Package contents

 

 

1 AirSim Pierre Robin X ready-to-use (PR10000X) 

 

1 AirSim Pierre Robin X carrier case (JBAG03) 

 

1 USB pen drive user manual  

 

100ml bottle of lubrication (TL001) 

 
 

Recommended equipment sizes 

 

3.5-4.0 mm ID for oral intubation 

 

Size 1 for supraglottic devices 

 

Size 1 for video-laryngoscopy 

 

Initial set-up information  

 

Gently remove the model from the carrier case 

 

 

Secure the manikin to a suitable surface by adjusting the screw on the suction cups 
(surface must be non-porous to ensure sufficient suction)

 

 

The head can be placed in a neutral or sniffing position by rotating the head, if required 
for direct laryngoscopy 

 

 

Please ensure two lung bags and one stomach bag are attached to the airway and 
oesophagus respectively 

 

 

Spray generous amounts of lubrication provided with the model (TL001) on the airway 
and equipment prior to use

 

Summary of Contents for AirSim Pierre Robin X

Page 1: ... in collaboration with clinicians from Children s Hospital of Los Angeles This realistic training manikin highlights difficult airway management techniques for infants with Pierre Robin Sequence Syndrome PRS The nasal cavity and airway include important internal landmarks for training in endo tracheal and nasotracheal intubations TruCorp are proud to offer a 5 year warranty on the AirSim X airway ...

Page 2: ...ntents Product specifications 3 Package contents 3 Recommended equipment sizes 3 Initial set up information 3 List of procedures facilitated by the AirSim Pierre Robin X 4 Care and maintenance 4 Warranty 4 ...

Page 3: ... devices Size 1 for video laryngoscopy Initial set up information Gently remove the model from the carrier case Secure the manikin to a suitable surface by adjusting the screw on the suction cups surface must be non porous to ensure sufficient suction The head can be placed in a neutral or sniffing position by rotating the head if required for direct laryngoscopy Please ensure two lung bags and on...

Page 4: ...e manufacturer s instructions and at the proper dilution The detergent must not contain skin or mucous membrane irritants Please do not use any of the following when cleaning the AirSim product range Germicides disinfectants or chemical agents such as glutaraldehyde e g Cidex Ethylene oxide phenol based cleaners or iodine containing cleaners In response to the recent COVID 19 pandemic we recommend...

Page 5: ...reight delivery of the TruCorp airway free of charge if the airway fails within the 5 year period However these warranties are VOID if the unit shows evidence of having been tampered with or shows evidence of having been damaged by excessive heat the use of sharp instruments misapplication misuse or other operating conditions outside of TruCorp s control Components which wear or are damaged by mis...

Reviews: