TRQ LYRA Series Manual Download Page 1

 

SELF CONTAINED EMERGENCY LUMINARY 
SERIE LYRA 

 

Characteristics: 

Supply 230 V 50/60Hz. 
Non Maintained. 
Verification TEST by TEST button incorporated or via TELEMANDO. 
Stand by and re-start via Telemando. 
Yellow Led indicating, the Battery re-charging. 
Autonomy more than 1, 2 or 3 hours (depending on the model) 
Grade IP65 IK07 or IP42 IK04, (depending on the model) 
Connection via 16 or 20 mm cable 
Protection against Overloading and end of Battery Discharge 
Protection against the connection errors of TELEMANDO CONNECTOR 
Class  II  Luminary,  should  be  installed  in  a  way  that  no  metal  piece  exposed  is  in  electrical 
contact with either in electrical installation or Conductor of protection. 
   

Norms Applied: 

CE as per directives 2006/95/EC LVD and 2004/108/EC of EMC 
Manufactured according to norms UNE-EN 60598-2-22, UNE 20-392-93 and in complying with 
the norms EN-55015 and EN 50082-1 of electromagnetic compatibility. 

-

 

Adapted to the Instructions of Low tension Electro technical Norm RBT and NBE CPI 96 of 
the Basic norm of Edification

 

Models Available: 

 

* Awaiting Certification. 
 
Install & connect the luminary to the main supply. 
Check that the Yellow Led indicator indicating the Charging process is lit. 
The  Batteries  are  supplied  Discharged  and  they  need  24  hours  to  be  charged  completely,  so 
the Luminary will not respond to its Autonomy until 24 hours.

.  

 
Maintenance: 

The Batteries should be changed once their duration gets inferior to the assigned. 
The Luminaries should be checked at least once a year.( We recommend every 3months) 
The Batteries and tubes should be re-cycled or eliminated in an adequate way. 
Before doing any maintenance operation, please make sure that the Main supply is switch off 
and the Luminary is in STAND BY Position.

 

 
 

Verification TEST: 

Verification test is possible with one of the following Accessories. 
MANUAL TEST BUTTON: By pressing this Button, the Luminary goes on Emergency Stage 
(Fluorescent Tube ON) 
TELEMANDO TM: By pressing the button Test ON, the Luminary starts working on Emergency 
in the presence of supply. 

 
Stand by position:

 

Connect the TELEMANDO TM as indicate din the Diagram of connection 
En Emergency stage it  is possible to  Switch OFFF the Luminary to save the  Battery  power by 
pressing OFF. By pressing ON the Luminary starts working again. 
 
 

 
Mod 
IP65 

 

Mod. 

IP42 

Emergency Lamp 

Battery 

Ni-Cd 

Autonomy 

φ

 Lumen 
output 

Lumen 

L-100E 

L-100 

T5 8W (G5) 

2.4V 1.5Ah 

1 Hour 

100* 

L-300E 

L-300 

T5 8W (G5) 

6V 1.5Ah 

1 Hour 

260* 

L-400E 

L-400 

PL-11W (2G7) 

6V 1.5Ah 

1 Hour 

352* 

L-500E 

L-500 

PL-11W (2G7) 

3.6V 4Ah 

1 Hour 

500* 

L-153E 

L-153 

T5 8W (G5) 

3.6V 4Ah 

3 Hours 

141* 

L-302E 

L-302 

T5 8W (G5) 

3.6V 4Ah 

2 Hours 

250* 

SIGN E 

SIGN 

T5 8W (G5) 

330* 

F

IP42

IP65

 

Lighting Technologies TRQ, S. L.

                                                               

Reviews: