6–
THIN LAYER SPECIAL CALIBRATION
The
Thin Lift Special Calibration
function allows the operator to re-
calibrate the gauge for materials not covered by the factory
calibration. Once a special calibration is enabled, it remains active
until the gauge is turned off, or until another calibration is enabled.
The thin layer special calibration uses the average of 3 to 20
measurements. Troxler recommends averaging one-minute readings
taken on a test site (see Figure 6–1 on page 6–13) or around a core
site (as shown in Figure 6–2). This average and the density obtained
by another method (such as core samples) are used to re-calculate
the gauge constants.
To access the
Thin Lift Special
functions, press the
〈
SPECIAL
〉
key.
At the
Special
functions menu, press
〈
1
〉
Special Operation.
At the
Special Operation
menu, press
〈
2
〉
Thin Lift Special.
The gauge
displays the
Thin Lift Special
menu:
The gauge displays a thin layer special calibration on the first line, if
one exists in gauge memory. The following text provides details on
the
Thin Lift Special
function.
Enable a Thin Layer Special Calibration
Use the arrow keys to scroll through the thin layer special
calibrations. When the gauge displays the thin layer special
calibration to be enabled, press
〈
1
〉
.
NOTE:
The 3450 gauge must be in Thin Layer mode to enable a
thin layer special calibration.
The gauge enables the selected thin layer special calibration and
returns to the
Ready
screen.
Thin Spec:Current
1-Enable Thin Spec
2-Disable
4-New
3-View
5-Erase
Summary of Contents for RoadReader Plus 3450
Page 7: ...Model 3450 vii NOTES...
Page 13: ...xii NOTES...
Page 17: ...1 4 GAUGE PARTS AND ACCESSORIES Figure 1 1 Model 3450 Parts and Accessories...
Page 23: ...2 4 Figure 2 1 Effect of Moisture on Depth of Measurement...
Page 53: ...3 28 NOTES...
Page 169: ...Appendix E 2 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 171: ...Appendix E 4 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 173: ...Appendix E 6 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 175: ...Appendix E 8 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 181: ...Appendix G 4 NOTES...
Page 187: ...Appendix H 6 NOTES...
Page 199: ...Index 12 NOTES...