4–10
SOIL MODE
To measure the moisture and density of soil, soil-stone aggregate,
and similar materials, follow the steps below:
✓
Select the
Soil
mode (see page 3–23).
✓
If desired, enter, change, or enable the Proctor value (see page
3–19).
✓
Prepare the test site as described on page 4–6.
✓
Place the gauge on the test area.
✓
Insert the source rod into the hole made by the drill rod or
source rod adapter.
Use care when inserting the source rod. Try
not to disturb the soil around the hole.
✓
Lower the source rod to the measurement depth. Release the
trigger. Gently tap down on the handle over the source rod to
lock the source rod into position. You should hear a
click
when
the source rod locks into position.
✓
Gently slide the gauge to the right (towards the keypad) so the
source rod makes contact with the wall of the hole.
✓
Press the
〈
START
〉
key.
►
In the
Manual
depth mode (see page 3–14), the gauge will
prompt for the source rod depth. Enter the source rod depth
using the number keys. For example, with the source rod in
the backscatter position, press
〈
0
〉
. Then press
〈
ENTER
〉
.
►
In the
Automatic
depth mode, the gauge software reads the
depth strip on the source rod to determine the source rod
depth.
►
Note that the Proctor value is based on soil particles 3/8
inches or less in diameter (or those passing a #4 sieve). If an
unusual reading is obtained and oversize particles are
suspected, rotate the gauge 90
°
. Use the same drill hole to
take a second reading.
Summary of Contents for RoadReader Plus 3450
Page 7: ...Model 3450 vii NOTES...
Page 13: ...xii NOTES...
Page 17: ...1 4 GAUGE PARTS AND ACCESSORIES Figure 1 1 Model 3450 Parts and Accessories...
Page 23: ...2 4 Figure 2 1 Effect of Moisture on Depth of Measurement...
Page 53: ...3 28 NOTES...
Page 169: ...Appendix E 2 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 171: ...Appendix E 4 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 173: ...Appendix E 6 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 175: ...Appendix E 8 STANDARD COUNT LOG Gauge Serial Number Date Moisture MS Density DS1 Density DS2...
Page 181: ...Appendix G 4 NOTES...
Page 187: ...Appendix H 6 NOTES...
Page 199: ...Index 12 NOTES...