5.2.5
The database mode
The operating mode "Database/PC" is not an operating mode intended for reading transponders, but it
is dedicated to the communication between the reader and a computer.
In the database Mode the content of the database in the reader may be transferred to the PC and back
again. This allows to process the data records in the PC, as well as to add further information such as
text, for example.
These operations will be performed in an easy way by using the "Reader Terminal" program (for Win-
dows operation systems). It was developed by AEG ID
to show the user the range of capabilities pro-
vided by the database mode. All the steps necessary to set up communication between the ARE H5
handheld reader and a PC are presented in an "interactive" way. The "Reader Terminal" program al-
lows a simple visualization of the data records, stored in the reader, and how they can be modified.
Furthermore it allows to change the setting of certain parameter (see also chapter 6).
The database mode is reached in the menu "Operating mode". Starting from "Stand-by" the buttons
have to be pressed in the following sequence:
Attribute
Stand-By
Operating Mode
MENU
MENU
Standard
Online
Online H
Read/Transf.
Database/PC
Important note: Correct function of the operating modes "Database/PC" or "Data->Serial" will
be achieved only, if the reader is connected properly to a computer. Such connection may be
realized either by using the special connection cable or via Bluetooth or Infrared link. Make
sure that the terminal is set for the specified data format (see ARE H5 Specifications in chap-
ter 7.1 and 7.8 ), especially if it is intended to use with individually made application software.
The ARE H5 handheld reader does not switch off automatically, when it is used in the database
mode. The user has to take care that the reader is set back to standard mode or online opera-
tion after he has completed the configuration changes; otherwise the batteries may be dis-
charged in a destructive way.
Normally the database mode is terminated from the PC. As an alternative it can be terminated by
simultaneously pressing the buttons "arrow right" and "arrow left".
The specification of the transfer protocol used in the database mode is given in chapter 0 as reference
[1]. It is intended for those users, who will generate their own specific application software.