background image

7

EN

Operating manual – dehumidifier TTP 5 E / TTP 10 E

The device is running, but there is no formation of
condensate:

Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.

Check the room temperature. Observe the device's
permissible ambient temperature according to the
technical data.

Ensure that the relative room humidity complies with the
technical data.

Check the air filter for dirt. If necessary, clean or replace
the air filter.

The device is loud or vibrates:

Check whether the device is set up in a stable and upright
position.

Condensate is leaking:

Check the device for leaks.

The device gets very warm, is loud or loses power:

Check the air inlets and air filters for dirt. Remove external
dirt.

From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.

Notice

Wait for at least 3 minutes after maintenance and
repair work. Only then switch the device back on.

Your device still does not operate correctly after these
checks?

Please contact the customer service. If necessary, bring the
device to an authorized specialist electrical company or to
Trotec for repair.

Maintenance

Activities required before starting maintenance

Warning of electrical voltage

Do not touch the mains plug with wet or damp hands.

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Cleaning the housing

Clean the housing with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.

Visual inspection of the inside of the device for dirt

1. Remove the air filter.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, have the inside of the

device cleaned by a specialist company or by Trotec.

5. Put the air filter back in.

Summary of Contents for TTP 10 E

Page 1: ...TRT BA TTP5E TTP10E TC 001 EN TTP 5 E TTP 10 E EN OPERATING MANUAL DEHUMIDIFIER ...

Page 2: ...g link TTP 5 E https hub trotec com id 41289 TTP 10 E https hub trotec com id 41290 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save ...

Page 3: ...n hose Discharge the collected condensate before transport and storage Do not drink it Health hazard Intended use Only use the device for keeping the room air in spatially limited areas dry whilst adhering to the technical data Intended use includes keeping the following dry small living spaces closets and shoe cabinets bookshelves pantries and storerooms small windowless bathrooms etc Improper us...

Page 4: ...humidified cooled air is blown out The drier air thus conditioned mixes with the air in the room The humidity in the room where the device is positioned is reduced as air constantly circulates through the device Depending on the air temperature and the relative humidity the condensed water drops into the condensation tank The latter is fitted with a float to measure the filling level If the maximu...

Page 5: ...e remaining condensate from the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device After transporting the device observe the following Set up the device in an upright position after transport Storage Before storing the device proceed as follows Drain the remaining condensate from the device and the condensation drain hose see chapter Mainte...

Page 6: ...ng hazards when laying the power cable or other electric cables especially when positioning the device in the middle of the room Use cable bridges Make sure that extension cables are completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas ...

Page 7: ...c shock 1 Press the on off switch 1 ð The LED at the on off switch is illuminated in green ð The fan switches on ð The device starts to dehumidify Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Empty the condensation tank if need be Clean the device according to the Maintenance...

Page 8: ... at least 3 minutes after maintenance and repair work Only then switch the device back on Your device still does not operate correctly after these checks Please contact the customer service If necessary bring the device to an authorized specialist electrical company or to Trotec for repair Maintenance Activities required before starting maintenance Warning of electrical voltage Do not touch the ma...

Page 9: ...ter make sure that it is undamaged and dry The air filter has to be cleaned as soon as it is dirty This is brought to light e g by a reduced capacity see chapter Errors and faults 1 Remove the air filter from the device TTP 10 E 2 Clean the filter using a slightly damp soft lint free cloth If the filter is heavily contaminated clean it with warm water mixed with a neutral cleaning agent 3 Allow th...

Page 10: ...r Clean the tank regularly using a mild cleaning agent no detergent 6 Refit the condensation tank into the device Make sure not to damage the float when inserting or removing the condensation tank In doing so make sure that the float is positioned correctly In doing so make sure that the condensation tank is inserted correctly for otherwise the device cannot be switched back on Activities required...

Page 11: ...cm 10 cm 10 cm 10 cm 10 cm 10 cm Weight 1 5 kg 2 kg Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment in your vicinity The addresses can be obtained from your mu...

Page 12: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: