16
EN
dehumidifier TTK 100 E
3. Rinse the condensation tank with clear water. Regularly
clean the condensation tank using a mild cleaning agent
(no detergent!).
4. Refit the condensation tank into the device.
Make sure not to damage the float when inserting or
removing the condensation tank.
In doing so, make sure that the float is positioned
correctly.
In doing so, make sure that the condensation tank is
inserted correctly, for otherwise the device cannot be
switched back on.
Activities required after maintenance
If you want to continue using the device:
•
Leave the device to rest for 12 to 24 hours, so the
refrigerant can accumulate within the compressor. Wait
12 to 24 hours before switching the device back on! Acting
contrary might lead to compressor damage and a
malfunctioning device. If so, any warranty claims will be
voided.
•
Reconnect the device to the mains.
If you do not intend to use the device for a considerable time:
•
Store the device according to the Transport and storage
chapter.
Technical annex
Technical data
Parameter
Value
Model
TTK 100 E
Dehumidifying capacity, max.
30 l / 24 h
Air flow rate
215 m
3
/h
Operating range (temperature) 5 °C to 32 °C
Operating range
(relative humidity)
30 % to 80 % RH
Pressure suction side
1.2 MPa
Pressure outlet side
2.4 MPa
Max. permissible pressure
2.6 MPa
Mains connection
220–240 V / 50 Hz
Max. power input
0.57 kW
Nominal current
2.4 A
Refrigerant
R290
Amount of refrigerant
122 g
GWP factor
3
CO
2
equivalent
0.000366 t
Water tank
4.3 l
Sound pressure level
(at a distance of 1 m)
50 dB(A)
Dimensions
(length x width x height)
274 x 390 x 612 mm
Minimum distance to walls and
other objects
A: top:
B: rear:
C: side:
D: front:
50 cm
50 cm
50 cm
50 cm
Weight