10
EN
oil-filled radiator TRH 28 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Note
The device is filled with the heating medium oil. Tasks
which require the oil tank to be opened must only be
carried out by Trotec. In case of oil leakage please
contact the customer service.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Wipe the housing dry after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TRH 28 E
Power
level 1:
level 2:
level 3:
1200 W
1300 W
2500 W
Mains connection
220 – 240 V / ~ 50 Hz
Number of heating fins
11
Nominal current consumption 10.9 A
Recommended mains fuse
16 A
Type of protection
IP20
Protection class
I /
Plug type
VDE plug CEE 7/7
Cable length
1.8 m
Suitable ambient temperature - 20 °C to +40 °C
Dimensions (length x width x
height)
446 x 240 x 635 mm
Minimum distance to walls and
other objects
top (A):
rear (B):
sides (C):
front (D):
100 cm
100 cm
100 cm
100 cm
Weight
10 kg
Information requirements for electrical local space heaters