Error messages
The following error messages can be indicated on the
display (15):
Message
Cause
Troubleshooting
Air pressure too low The fan does not run Restart the device
and check the fan
for proper
functioning
Filter dirty
The air filter might
be contaminated
Replace the filter
Overheating
protection room
temperature
The adjusted room
air temperature has
been exceeded
Switch the device
off and allow the
room to cool down
Overheating
protection motor
The device is
overheating
Disconnect the
device from the
mains and allow to
cool down
Sensor fault
Defective
temperature sensor
Switch the device
off and check the
temperature sensors
Maintenance
Trotec electric heaters are designed for long hours of operation
with minimum maintenance effort. Safe operation of the device
requires all built-in components, especially the safety
temperature limiter (STB), to be checked and cleaned
after 6 months at the latest or after every 4,000 operating hours
as well as all damaged components to be replaced.
Prior to cleaning the interior, protect the fan and further
electrical components from water ingress with appropriate
means.