14
EN
cordless pruning shears PGSS 15-20V
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug or the battery with wet or
damp hands.
•
Switch the device off.
•
Allow the device to cool down completely.
•
Remove the battery from the device.
Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.
Notes on maintenance
•
Keep the blade sharp and free of rust by regularly checking
it and greasing it with suitable grease or penetrating oil.
Inside the device, there are no parts that need to be maintained
or lubricated by the user.
Safety signs and labels on the device
Check the safety signs and labels attached to the device at
regular intervals. Replace illegible safety signs!
Safety signs on the battery and the charger
Check the safety signs attached to the battery and the charger
at regular intervals. Replace illegible safety signs!
Cleaning
The device should be cleaned before and after each use.
Warning of electrical voltage
There is a risk of a short-circuit due to liquids
penetrating the housing!
Do not immerse the device and the accessories in
water. Make sure that no water or other liquids can
enter the housing.
•
Clean the device with a soft, damp and lint-free cloth.
Make sure that no moisture enters the housing. Protect
electrical components from moisture. Do not use any
aggressive cleaning agents such as cleaning sprays,
solvents, alcohol-based or abrasive cleaners to dampen
the cloth.
•
Dry the device with a soft, lint-free cloth.
•
Clean the blades with a soft brush and oil them with
universal oil spray after each use.
•
Keep the connecting terminals on the device and charger
clean.
Replacing the cutting blade
Warning of hand injuries
There is a risk of injury from cuts in the area of the
blade if the device is handled without due care. Never
reach into the blade. Always keep the blade away from
your body and from other people nearby.
Info
Self-locking nuts may only be used once. Use a new
self-locking nut to mount a new blade.
If the movable cutting blade is blunt or worn, it must be
replaced.
ü
The device is switched off.
ü
The battery is removed from the device.
1. Remove the self-locking nut (M8, SW13) (
14
), the wave
washer (
15
) and the washer (
16
).
2. Remove the screw bolt (
17
).
3. Remove the old cutting blade (
13
).
17
13
16
15
14
4. Insert the new cutting blade.
5. Reinsert the new screw bolt (
17
).
6. Place the washer (
16
) and the wave washer (
15
) on the
screw bolt (
17
).
7. Tighten a new self-locking nut (M8, SW13) on the screw
bolt (
17
).
13
16
15
14
17