Trotec PCPS 10-1100 Original Instructions Manual Download Page 8

7

EN

compressor PCPS 10-1100

Technical data

Parameter

Value

Model

PCPS 10-1100

Max. pressure

8 bar (116 psi)

Max. air flow rate

10.8 m

3

/h

Suction capacity

approx. 180 l/min

Idle speed

3550 rpm

Weight

6.0 kg

Nominal voltage

~ 230 V / 50 Hz

Power consumption

1100 W

Nominal current

4.5 A

Operating mode

S3 15 % 10 min*

Cable length

5 m

Hose length

3 m

Hose diameter

12 mm

Protection class

II / 

Sound values according to
ISO 2151

Sound pressure level L

pA

94.1 dB(A)

Uncertainty K

pA

3 dB(A)

Sound power level L

WA

95.1 dB(A)

Uncertainty K

WA

1.94 dB(A)

*Operating mode S3 15 % 10 min: This compressor is
designed for intermittent operation. This means that over a
period of 10 min the maximum switch-on time may be 15 %
(1.5 min).

Wear hearing protection.

Excessive noise can lead to hearing loss.

Information on noise and vibration:

The specified noise emission values were measured by
means of a test procedure standardized in ISO 2151 and
can be consulted for the comparison of one power tool
with another.

The specified noise emission values can also be used for
preliminary load assessment.

The actual noise emission may differ from the stated
values during operation of the power tool. This depends on
how the power tool is used and especially on the type of
workpiece being processed.

Transport and storage

Note

If you store or transport the device improperly, the
device may be damaged.
Note the information regarding transport and storage of
the device.

Transport

Before

 transporting the device, observe the following:

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down.

Storage

Before

 storing the device, observe the following:

Switch off the device.

Hold onto the mains plug while pulling the power cable out
of the mains socket.

Allow the device to cool down.

Clean the device as described in the Maintenance chapter.

When the device is not being used, observe the following
storage conditions:

dry and protected from frost and heat

ambient temperature below 40 °C

the compressed-air hoses must not be kinked

protected from dust and direct sunlight

Start-up

Unpacking the device

Take the device and the accessories out of the packaging.

Warning of electrical voltage

Electric shock from insufficient insulation.
Check the device for damages and proper functioning
before each use.
If you notice damages, no longer use the device.
Do not use the device when the device or your hands
are damp or wet!

Check the contents for completeness and look for
damages.

Warning

Risk of suffocation!
Do not leave the packaging lying around. Children may
use it as a dangerous toy.

Dispose of the packaging material according to the
national regulations.

Summary of Contents for PCPS 10-1100

Page 1: ...TRT BA PCPS10 1100 TC 002 EN PCPS 10 1100 EN ORIGINAL INSTRUCTIONS COMPRESSOR...

Page 2: ...r hearing protection Information marked with this symbol indicates that you should wear hearing protection Wear safety glasses Information marked with this symbol indicates that you should wear eye pr...

Page 3: ...a power tool outdoors use an extension cord suitable for outdoor use Use of a cord suitable for outdoor use reduces the risk of electric shock If operating a power tool in a damp location is unavoida...

Page 4: ...s maintained Device specific safety warnings for compressors and blow out guns Do not use the device in potentially explosive rooms Ensure that the side of the device where the air inlet is found is k...

Page 5: ...nd beach items for measuring the current pressure level of an inflatable object for generating compressed air for pneumatic tools whilst adhering to the technical data Info Please note that the pressu...

Page 6: ...distance from heat sources Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Note The device is not sui...

Page 7: ...ation 1 Transport handle 2 On off switch with protective cover 3 Storage compartment for compressed air hose 4 Compressed air hose with quick coupling 5 3 fold nozzle attachments 6 Ball needle 7 Unive...

Page 8: ...ce being processed Transport and storage Note If you store or transport the device improperly the device may be damaged Note the information regarding transport and storage of the device Transport Bef...

Page 9: ...m the system 2 Pull back the sleeve 28 at the quick coupling 21 of the compressed air hose 4 Hold the quick coupling steady in your hand to prevent uncontrolled release 28 3 Take the released compress...

Page 10: ...as follows The device is switched off 1 If the compressed air gun is already connected to the compressor disconnect it from the compressor first see chapter Disconnecting the compressed air gun 2 Use...

Page 11: ...scale for psi Measures the pressure in psi 27 Indicator scale for bar Measures the pressure in bar 28 Indicator needle Indicates the current pressure value in psi and bar Checking the pressure 1 Conn...

Page 12: ...r becomes sluggish and can be difficult or impossible to start up Do not use the device at an temperatures below 5 C The device is running but there is no apparent inflation The pressure gauge shows n...

Page 13: ...after cleaning Warning of electrical voltage There is a risk of a short circuit due to liquids penetrating the housing Do not immerse the device and the accessories in water Make sure that no water o...

Page 14: ...l Product PCPS 10 1100 Product type compressor Year of manufacture as of 2018 Guaranteed sound power level LWA 97 dB A Relevant EU directives 2000 14 EC 8 May 2000 2005 88 EC 14 Dec 2005 2011 65 EU 1...

Page 15: ......

Page 16: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: