Trotec PAC 2000 X Operating Manual Download Page 1

PAC 2000 X

TR

T-BA-P

A

C2000X

-T

C-006-EN

OPERATING MANUAL

LOCAL AIR CONDITIONER

EN

Summary of Contents for PAC 2000 X

Page 1: ...PAC 2000 X TRT BA PAC2000X TC 006 EN OPERATING MANUAL LOCAL AIR CONDITIONER EN ...

Page 2: ...ical changes All rights reserved Trademarks are used without guarantee that they may be used freely and primarily following the spelling of the manufacturer Product names are registered Changes to construction in the interests of constant improvements to the product as well as changes to the shape and colour are reserved The scope of delivery may vary from product images This document was created ...

Page 3: ...aust air hose cooled air is fed to the installation site by means of a fan Accumulating condensate drips from the evaporator onto the hot condenser there it evaporates and then is transported to the outside via the exhaust air hose Excess condensate is dripping from the condenser into a condensate trap and is there re fed to the condenser by use of a paddle wheel where it evaporates and is dischar...

Page 4: ...sed rooms whilst adhering to and following the technical data Improper use Do not place the device on damp or flooded ground Do not use the device outdoors Do not place any objects e g wet clothing on the device for drying Any unauthorised changes modifications or alterations of the device are forbidden Personnel qualifications People who use this device must be aware of the dangers that occur whe...

Page 5: ...ing the device When positioning the device observe the minimum distance from walls or other objects as described in the chapter Technical data Set the device up in a level upright and stable position Do not create tripping hazards when laying the power cable or other electric cables Make sure that no curtains or other objects interfere with the air flow Connecting the exhaust air hose 1 Slightly t...

Page 6: ... so open the cover of the battery compartment at the back of the remote control Insert the battery observing the correct polarity Go by the marking inside the battery compartment Then close the battery compartment Check air inlets and outlets for foreign objects and remove these if necessary Check the air filter for dirt and clean it if required Also see chapter Maintenance Switching the device on...

Page 7: ...the minimum limit is 15 C 5 LED display The display indicates the current temperature or timer settings If the set temperature or timer value is to be adjusted the new setting will be indicated then the display returns to the currently set temperature The display also serves to indicate error messages in case of a fault see ERROR CODES 6 SPEED Press this button to adjust the fan speed During heati...

Page 8: ... the timer Timer off TIMER OFF is used to turn the device off automatically after the set time has passed Press the TIMER button 7 during operation to set the desired time Once the set number of hours has lapsed the device will switch off automatically If you press the POWER button 1 before the time has expired the device will switch off and the set time will be deleted Sleep control function Note...

Page 9: ... 3 Clean the device and especially the air filter according to chapter Maintenance 4 Store the device according to the Storage chapter The device has been checked for proper functioning several times during production If malfunctions occur nonetheless check the device according to the following list Your device still does not operate correctly after these checks Bring the device to a specialist co...

Page 10: ...necessary x x Replace the air filter x Check for damage x Check the attachment screws x x Test run x Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air inlet grid and air filter for dirt and foreign objects and clean or...

Page 11: ...ee a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air conditioning or by Trotec 4 Put the air filter back in Cleaning the housing Clean the device with a soft damp and lint free cloth Ensure that no moisture enters the housing Do not use any sprays solvents alcohol based cleaning agents or abrasive cleaners Only use clean water to moisten the cl...

Page 12: ...ed restart the device then the unit can operate normally Cleaning the air inlets and the air filter Caution Ensure that the air filter is not worn or damaged The corners and edges of the air filter must not be deformed or rounded Before reinserting the air filter make sure that it is undamaged and dry Read the chapter Maintenance intervals and replace the air filter in due time A B ...

Page 13: ...m The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effects for the environment and human health caused by the disposal of hazardous substances potentially contained in the equipment You are responsible for deleting any personal data stored on the waste equipment to ...

Page 14: ...s Cooling Mode A Energieeffizienzklasse im Heizbetrieb Energy Efficiency Class Heating Mode A Indikativer Stromverbrauch pro Stunde im Kühlbetrieb Electricity Consumption Cooling Mode QSD kWh 60 min 0 8 Indikativer Stromverbrauch pro Stunde im Heizbetrieb Electricity Consumption Heating Mode QSD kWh 60 min 0 6 Nennleistung im Kühlbetrieb Nom Power Cooling Mode Prated kW 2 0 Nennleistung im Heizbet...

Page 15: ...eizbetrieb Set Temperature Range Heating Mode C 15 25 max Luftvolumenstrom max Air Flow Volume m3 h Netzanschluss Power connection Nennstrom Nom Current A Schalldruckpegel Sound Pressure Level dB A Gewicht Weight kg Abmessungen Dimensions BxHxT WxHxD mm cm Mindestabstand zu Wänden Gegenständen Minimum distance to walls and objects 428x625x288 50 360 1 N PE 220 240 V 50 Hz 3 9 50 26 5 17 30 5 35 1 ...

Page 16: ......

Page 17: ......

Page 18: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: